PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
130620-293 <br />F. in -Tank Gauging / SIR Equipment: ii Check this box If tank gauging is used only for inventory control. <br />® Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed If in4ank gauging equipment Is used to perform leak detection monitoring. <br />A -22-2— <br />s Yes <br />r3 No` <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />m Yes <br />® No- <br />Were all tank gauging probes visually Inspected for damage and residue buildup? <br />51 Yes <br />No` <br />Was accuracy of system product level readings tested? <br />Yes <br />No' <br />Was accuracy of system water level rungs tested? <br />Yes <br />No` <br />Were all probes reinstalled property? <br />� Yes <br />No" <br />Were all items on the equipment manufacturers maintenance checklist completed? <br />In the Section H, below, describe flow and wnen tnese oenctencies were or wni oe correcma. <br />G. Line Leak Detectors (LLD): R Check this box if LLDs are not installed. <br />® Yes <br />No• <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all <br />N/A <br />that ) Simulated leak rate: ®3 g p.h.; ®0.1 g.p.h ; 13 0.2 g.p.h. <br />Yes <br />No' <br />Were all LLDs confirmed operational and agate within regulatory requirements? <br />Yes <br />No` <br />Was the testing apparatus properly calibrated? <br />13 Yes <br />1W <br />For mechanical LLDs, does the LLD restrict product flow If it detects a leak? <br />N/A <br />Yes <br />No' <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />WA <br />Yes <br />NO* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or <br />WA <br />disconnected? <br />Yes <br />No` <br />For AxAmnic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or <br />WA <br />falls a test? <br />Yes <br />No' <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />13 WA <br />Yes <br />a No` <br />I Were ail Reins on the equipment manufacturer's maintenance checklist completed? <br />A 1T --V ' UM11;A71F,7M--r--,7 iIc77Ti TZ;.. � Ii- I11 -Mf a, ]IN![ lA"I .r.z•:r ^iEn•=i«.•�wr :�c .,, <br />H. Comments: <br />Suction system. <br />Monitoring System Certification Rage 3 of 4 <br />12J07 <br />3 2/21/07 <br />