Laserfiche WebLink
r Spill Containment— OPW EVR Thread-on or OPW/POMECO EVR Multi-Port Spill Containers are <br /> certified for installation on the OPW Phase 1 PVR system.All fill ports in these spill containers <br /> _ feature enhanced 1 DK-2100-EVR vapor tight drain valves that exceed the EVR requirements for <br /> a maximum vapor leak rate of 0.17CFH at 2.0 inches H2O.The vapor return spill containers <br /> feature a permanent plug installed in the drain ports, as per EVR requirements. <br /> Overfill Prevention —The OPW 61 SO-40OC-EVR Series Overfill Prevention Valves are certified for <br /> installation on the OPW Phase 1 EVR system.The vapor tight EVR 61 SO's are designed to provide <br /> positive shut-off of product delivery, before an overfill condition occurs, per EPA requirements, <br /> q without intervention from the transport driver.The valve features a sealed float pivot and a <br /> threaded lower tube connection,and exceeds the EVR requirement for a maximum vapor leak <br /> rate of 0.17CFH at 2.0 inches H2O.The 61 SO-EVR Series Valve is installed in the base of the OPW <br /> EVR Spill Container with the patent pending 611SK lack Screw device.This config <br /> uration allows <br /> . <br /> liquid in the spill container to be drained directly into the drop tube,thereby isolating the drain <br /> valve from the tank ullage,eliminating a notorious leak point in previous systems. <br /> Tank Bottom Protector-The OPW/POMECO 6111-1400 Tank Bottom Protector is EVR certified <br /> for installation at the bottom of the overfill prevention valve drop tube to help prevent the <br /> damage from erosion or tank gauging sticks. <br /> underground storage tank from sustaining <br /> _ K . <br /> a <br /> Ball Float and 233 Extractor—The OPW 53VML Ball Float, 233 Extractor and <br /> 61T Fill Drop Tube configuration can be installed as an alternative to the 6150 <br /> Overfill application.The installation of the Ball Float/Drop Tube system is <br /> identical to the 61 SO Overfill Valve on the OPW Phase 1 Vapor Recovery System. <br /> Rotatable Swivel Adaptors (Fill and Vapor) —OPW EVR Rotatable Swivel Adaptors are certified <br /> for installation on the fill and vapor ports on the OPW Phase 1 EVR system. OPW Swivel Adaptors <br /> P <br /> 360 degrees of rotation of any product or vapor recovery elbow to prevent the adaptors <br /> from loosening on the spill container risers.OPW Svulvel Adaptors exceed the EVR requirement to <br /> maintain a minimum 360-degree rotation with an average static torque not to exceed 108 inch- <br /> pounds (9 foot-pounds).The enhanced poppet system on the OPW 61VSA-EVR vapor swivel <br /> adaptor provides a vapor tight seal when closed, per EVR requirements. <br /> Adaptor Tool —An OPW 61 SA TOOL is required to ensure proper installation of OPW Rotatable <br /> Swivel Adaptors, spill containers and threaded riser adaptors, per EVR requirements.The <br /> i" <br /> 61S <br /> ATOOL includes provisions for the use of a torque wrench to facilitate accurate installation <br /> And testing. <br /> Dust Caps(Fill&Vapor)—OPW EVR Dust Caps are certified for installation on <br /> OPW EVR Certified Rotatable Adaptors. OPW EVR Certified Dust Caps feature <br /> enhanced ribbed seals and increased sealing forces to provide a bubble-tight <br /> < seal, per EVR requirements.Available in Duratuff or low-profile metal models. <br /> Threaded Riser Adaptor(Face Seal Adaptor)—An OPW FSA-400 Threaded Riser Face Seal <br /> Adaptor is required to provide a flat,true sealing surface on threaded pipes where a gasket seal <br /> exists per EVR requirements.The FSA-400 is installed on the fill pipe riser below the spall <br /> container to provide a true sealing surface for the drop tube flange on the 61 SO-4000-EVR <br /> Overfill Prevention Valves.The FSA-400 is also required on tank gauging risers,though is <br /> optional on vapor risers and rotatable adaptors. <br /> Pressure Vacuum Vent—The OPW 623V Pressure Vacuum Vent is certified for installation on the <br /> OPW Phase 1 EVR system.The 623V's are installed on the top of the vent pipes for underground <br /> fuel storage tanks.The vent cap and internal wire screen are designed to protect the tank et nn <br /> lines against intrusion and blockage from water, debris or insects.A normally closed pope <br /> the valve opens at a predetermined pressure or vacuum setting to allow the tank to vent The <br /> 623V exceeds the EVR requirement of a maximum vapor leak rate of 0.17CFH at 2.0 inches H2O. <br />