Laserfiche WebLink
SAN JOAQUIT, UNTY ENVIRONMENTAL HEALTOPARTMENT r <br /> 600 E. Main St. • Stockton, CA 95202-3029 Phone(209)468-3420 <br /> ` r Donna Heran, R.E.H.S., Director <br /> s .Y ENVIRONMENTAL HEALTH 4 }$= a <br /> T` - }v. M5 <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY ` ",=r <br /> PERMIT TO OPERATE x ' <br /> Program Permit Permit <br /> Record ID Number Program Code and Description <br /> Valid <br /> PRO518529 PT0012081 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY -1/1/2010 To 12/31/2010 <br /> Hazardous Waste Generator Program: <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20,Chap.6.5,Art.2-13, v t <br /> Sec.25100 et seq,,and Title 22,California Code of Regulations,Chap.20_ x <br /> - - - - <br /> PR0231426 2300-UNDERGROUND STORAGE TANK FACILITY a1112010 To 12/31/2010 <br /> Caldifo nia He th and Safet Code Div.20,Cha_6.7 and Title 23,California Code of Re ulations Cha <br /> Storage _ <br /> 16 <br /> P/E Tank# Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection <br /> 2362 11 390002314260507923 PT0009397 1,500 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 12 390002314260507924 PT0009398 1,500 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitorings`' <br /> 2360 13 390002314260507925 PT0009399 12,000 REGULAR UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial MonitoringAl <br /> 2360 14 390002314260507926 PT0009400 6,000 REGULAR UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 .';'<15 390002314260507927 PT0009401 9,000 DIESEL Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 16 390002314260507928 PT0009402 6!000 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring � <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions N' <br /> 2) In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCA,Title 23,Chap.16 and 18,as well as any conditions <br /> a' established by San Joaquin County. <br /> r <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both J "fir <br /> n the Tank Owner and tank Operator receive a copy of the permit. ' <br /> '-Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved <br /> Monitoring,response,and plot plans shall be maintained onsite with the permit. �« <br /> 3�..;The Permittee shall comply with the monitoring procedures referenced in this permit 4�4 a <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and-A,V'- <br /> provide <br /> provide documentation of such servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized,release,the Permitee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring <br /> performed. ,y <br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change", <br /> '`' 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to revievv,inodification or � k <br /> revocation. ex <br /> 11 Construction,repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment. <br /> 12) The Permittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of the date of the issuance of this penmE p <br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. 1 r r f <br /> 14) A Copditional"Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated. <br /> PERMITS TO OPERATE are NOT TRANSFERABLE <br /> ..' and maybe SUSPENDED or REVOKED for cause r ; <br /> 1 <br /> PERMIT(s)Valid only for: CHAHOUD, PIERRE TONY <br /> r , <br /> X DBA: QUICK STOP s <br /> . F Tank Owner: FRANK GUINTA JR <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility: QUICK SHOP x , Facility ID FA0004625 <br /> 2072 W YOSEMITE AVE x Account ID AR0004954" zt � <br /> MANTECA CA 95337 r '.' Issued 2/10/2010 <br /> r <br />