My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2023 4:26:49 PM
Creation date
6/23/2020 6:48:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
YOSEMITE PETROLEUM
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231426_2072 W YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />The following is an itemized list of underground storage tank violations that have not <br />been addressed for QUICK SHOP as of December01, 2017. <br />Open violations from September 19, 2017 inspection <br />Violation #101 -No permit to operate. <br />A permit to operate the UST system has not been issued for the 100 -octane and 110 -octane UST tanks. No person <br />may own or operate an UST unless a permit for its operation has been issued by the local agency to the owner or <br />operator of the UST system. Immediately obtain a permit to operate a UST system from the EHD. An "Operating <br />without a Permit" penalty applies. <br />Violation #113 - Failed to submit monitoring system certification test report within 30 days. <br />A monitoring system certification, leak detector testing, and spill container testing were performed on March 31, <br />2017. A test report has not been submitted to the EHD or the California Environmental Reporting System (CERS). <br />A copy of the test report must be submitted within 30 days of the test. Immediately provide this report to the EHD. <br />Violation #121 - Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on March 31, 2017 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by April 30, 2017. This <br />information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br />inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br />actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br />corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />Violation #201 - Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. A cold start was performed in <br />May 2017 and testing report was not found on site. These records shall be maintained on site for at least three <br />years. Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment <br />calibration and maintenance records; (3) results of any visual observations; (4) results of sample analysis performed <br />a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or <br />other test results; (6) results of inventory readings and reconciliations. Immediately locate and maintain all <br />maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br />Violation #203 - Failed to maintain records of monitoring, repair, lining, and upgrades on site. <br />Records of repairs, linings, and upgrades for the UST system were not found on site. Site had a spill container <br />replaced based on service request SR0077716 and records were not found on site. These records shall be kept on <br />site for the life of the tank. Immediately locate and maintain these records on site and submit copies to the EHD. <br />Violation #204 - Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. Monitoring plans for tank ID numbers <br />TA0507923, TA0507924, TA0507926, TA0507927 and TA0507928 were not found on site.. A copy of these plans <br />shall be accessible on site at all times. Immediately locate and retain a copy on site. <br />Violation #206 - Failure to comply with UST operating permit conditions. <br />Upon the inspection of onsite records it was found that work requiring the notification or issuance of a permit by the <br />EHD prior to beginning of work was performed. According to the 5/12/2017 designated operator monthly report, a <br />"cold start" was performed during that month. Emergency repairs relating to UST system monitoring and release <br />detection may be performed by a properly licensed, trained and certified contractor pursuant to the EHD's policy and <br />a permit obtained within one business day from the EHD. All other repairs must have a permit submitted to and <br />approved by the EHD prior to beginning work. To date, the EHD does not have evidence of notification for the"cold <br />start". A full permit needs to be obtained for the replaced parts and a permit fee will be charged. <br />Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.