COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2023 4:26:49 PM
Creation date
6/23/2020 6:48:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
YOSEMITE PETROLEUM
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231426_2072 W YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L' <br />The following is an itemized list of underground storage tank violations that have not <br />been addressed for QUICK SHOP as of December01, 2017. <br />Open violations from March 22, 2016 inspection <br />Violation #328 - Failed to comply with temporary closure requirements. <br />The 100 and 110 -octane UST system was found to be illegally abandoned. This violation was fist noted on the <br />Notice to Abate Immediately issued by the EHD on 4-13-2013. A permit to repair the failed 100 -octane spill <br />container was obtained on 3-6-2015, no spill container repairs were conducted at this time. Furthermore, the <br />100 -octane turbine has a disconnected power source. Mr. Chahoud stated that the entire concrete slab over the <br />split 100, 110, and diesel split tank is sinking due heavy vehicular traffic in that area. No person shall abandon an <br />UST system without complying with the requirements of HSC 25298. Mr. Chahoud , tank owner, states the UST <br />system will be reused but he has no funds to repair it at this time. Immediately obtain a permit from the EHD to <br />temporarily close this UST system. A permit application was submitted to the EHD for the temporary closure, <br />however since the permit application was not complete it was not approved at this time, submit all the required <br />information for the above permit application and temporarily close this UST system, as required. <br />Open violations from March 27, 2015 inspection <br />Violation #325 - Spill container failed to contain a minimum capacity of five gallons. <br />The 100 -octane direct -bury spill container failed when tested. All spill containers shall have a minimum capacity of <br />five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue <br />deposition of petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and <br />certified contractor under permit and inspection of the EHD. If the spill container can't be replaced immediately, <br />there is a possibility that the 100 -octane UST system may be red tagged to prevent fuel inputs. Product level in the <br />100 -octane tank was reported as 877 -gallons. <br />Open violations from February 20, 2015 inspection <br />Violation #113 - Failed to submit monitoring system certification test report within 30 days. <br />A monitoring system certification, leak detector testing, and spill container testing were performed on September 23, <br />2013 and a test report has not been submitted to the the EHD or to the California Environmental Reporting System <br />(CERS). A copy of the test report must be submitted within 30 days of the test. Immediately provide a copy of <br />above test report to the EHD or log into CERS at http://cers.calepa.ca.gov and upload a copy of the test report as a <br />miscellaneous State -Required Document in the Underground Storage Tank section. This is a repeat violation, <br />Class II. <br />Violation #121 - Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on September 23, 2013 and an inspection report was issued identifying information to <br />be submitted to bring this site into compliance. This information was required to be submitted by October 23, 2014. <br />This information has not been received resulting in a non-compliant status for this facility. Multiple follow up letters <br />were sent to this facility detailing the outstanding violations and the required corrective actions. No return to <br />compliance documentation was received for May 31, 2011, September 28, 2011, and September 28, 2013 routine <br />UST inspections. Immediately complete and submit copies of respective return to compliance documentation with <br />statement of how each historical violation was corrected, including supporting documentation. <br />An operator that receives an inspection report shall have 30 days to submit a written response that includes a <br />statement documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a <br />written response documenting corrective actions taken or proposed is submitted within 30 days of receiving an <br />inspection report. Immediately provide complete and accurate return to compliance documentation for all the <br />aforementioned inspections. This is a Class II violation. <br />Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.