My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2023 4:26:49 PM
Creation date
6/23/2020 6:48:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
YOSEMITE PETROLEUM
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231426_2072 W YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r- -I <br />Ah <br />qW NW <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s4-qov.org/ehd <br />A Underground-St6ra% UcnkPiriM-Insot qtiqp,.Reprt <br />Facility Name: <br />QUICK SHOP <br />Facility Phone: <br />(209) 824-6700 <br />Date: <br />September 19, 2017 <br />Facility Address: <br />2072 W YOSEMITE AVE, MANTECA, CA 95337 <br />CERS ID: <br />10181669 <br />Inspection Contact: <br />Pierre Chahoud <br />Title: <br />Owner <br />Phone: <br />(209) 824-6700 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - LIST FACILITY <br />Consent For: <br />9 Inspection 9 Photos N Samples <br />I Consent Given By: <br />I Pierre Chahoud, Owner <br />Service Technician Onsitec Exp. Date: <br />Felix Ramirez 11/22/2018 <br />Designated Operator: Exp. Date: <br />Felix Ramirez 02/26/2018 <br />Service Technician Manufacturer's Training <br />Veeder Root, 07/06/18; VMI, 11/06/17; Tank Tester,05/31/20 <br />GGR California Code of Regulations HSC Health and Safety Code CIFIR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />F,116 Review <br />101 <br />HSC 25284 <br />No permit to operate <br />n V m R o COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V o R c COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />o V o R Li COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />o V Ei R Ei COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />Ei V E R o COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />Li V o R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />ii V Ei R o COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />Ei V Ei R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />ci V c R o COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />o V o R o COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />o V o R Li COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />Li V o R c COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />m V m R ii COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />E V ii R o COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />o V o R o COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />o V ci R o COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />Li V Ei R o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />o V o R o COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />o V o R o COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />Li V c R o COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />m V n R Ei COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />Li V E R o COS <br />b" cordi <br />201 <br />CCR 2712(b) 7Failed <br />to maintain alarm logs and/or records of follow up actions —7,V ❑ R 0 COS <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />EiV EiR o COS <br />203 <br />CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />mV iiR c COS <br />FA0004625 PR0231426 SCO01 09/19/2017 <br />EHD 23-01 Rev. 09/22/16 Page 1 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.