My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1151
>
2300 - Underground Storage Tank Program
>
PR0231429
>
COMPLIANCE INFO_2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2022 2:00:32 PM
Creation date
6/23/2020 6:48:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017
RECORD_ID
PR0231429
PE
2361
FACILITY_ID
FA0000819
FACILITY_NAME
ONE STOP MARKET*
STREET_NUMBER
1151
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
21641001
CURRENT_STATUS
01
SITE_LOCATION
1151 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231429_1151 W LOUISE_2017.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department A <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232a-0i <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage,Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ONE STOP MARKET* 1151 W LOUISE AVE, MANTECA December 04, 2017 <br /> SUMMARY OF)(IOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and is not approved by the EHD. <br /> For all three tanks, in the section Under Dispenser Containment(UDC) Monitoring, change 'yes' to 'no' for'UDC <br /> monitoring stops flow of product at dispenser.' <br /> For all three tanks, in the section under periodic testing, change 'no'to 'yes' for spill bucket testing. <br /> For all three tanks, fill the second person having responsibility section. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 12/5/2016 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by 1/4/2017 . This <br /> information was received late. An operator that receives an inspection report shall have 30 days to submit a written <br /> response that includes a statement documenting corrective actions taken or proposing corrective actions which will <br /> be taken. Ensure that a written response documenting corrective actions taken or proposed is submitted within 30 <br /> days of receiving an inspection report. <br /> This is a Class II violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to attach an alarm to the August 2017 designated operator monthly inspection report <br /> and failed to check that they were responded to appropriately. The 1-8: 87 Annular sensor was missing. During the <br /> monthly inspection, the designated operator shall review the alarm history for the previous month, check that each <br /> alarm was documented and responded to appropriately, and attach a copy of the alarm history with documentation <br /> taken in response to any alarms to the monthly report. Ensure that designated operators performing monthly <br /> inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> The fuel filter on the left hand side of the 3/4 dispenser(looking at it)was observed dripping liquid indicating a leak <br /> with the filter. The liquid was falling outside of the the under dispenser containment(UDC) unit. The underground <br /> storage tank system shall be operated to prevent unauthorized releases. Immediately stop the leak and clean up <br /> the area where the dripping is occurring. <br /> This is a Class II violation. <br /> FA0000819 PR0231429 SC001 12/04/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.