San Joaquin County <br /> Environmental Health Department A <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232a-0i <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage,Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ONE STOP MARKET* 1151 W LOUISE AVE, MANTECA December 04, 2017 <br /> SUMMARY OF)(IOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and is not approved by the EHD. <br /> For all three tanks, in the section Under Dispenser Containment(UDC) Monitoring, change 'yes' to 'no' for'UDC <br /> monitoring stops flow of product at dispenser.' <br /> For all three tanks, in the section under periodic testing, change 'no'to 'yes' for spill bucket testing. <br /> For all three tanks, fill the second person having responsibility section. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 12/5/2016 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by 1/4/2017 . This <br /> information was received late. An operator that receives an inspection report shall have 30 days to submit a written <br /> response that includes a statement documenting corrective actions taken or proposing corrective actions which will <br /> be taken. Ensure that a written response documenting corrective actions taken or proposed is submitted within 30 <br /> days of receiving an inspection report. <br /> This is a Class II violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to attach an alarm to the August 2017 designated operator monthly inspection report <br /> and failed to check that they were responded to appropriately. The 1-8: 87 Annular sensor was missing. During the <br /> monthly inspection, the designated operator shall review the alarm history for the previous month, check that each <br /> alarm was documented and responded to appropriately, and attach a copy of the alarm history with documentation <br /> taken in response to any alarms to the monthly report. Ensure that designated operators performing monthly <br /> inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> The fuel filter on the left hand side of the 3/4 dispenser(looking at it)was observed dripping liquid indicating a leak <br /> with the filter. The liquid was falling outside of the the under dispenser containment(UDC) unit. The underground <br /> storage tank system shall be operated to prevent unauthorized releases. Immediately stop the leak and clean up <br /> the area where the dripping is occurring. <br /> This is a Class II violation. <br /> FA0000819 PR0231429 SC001 12/04/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />