Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.smgov.org/ehd <br /> [1nderground Storage Tanlagrain � spectr deportJl <br /> Facility Name: Facility Address: Date: <br /> ONE STOP MARKET' 1151 W LOUISE AVE, MANTECA December 04, 2017 <br /> SUM",r OPWO ►viol s <br /> (GLASS I CLASS 11 or MINOR otFca to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1),2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and is not approved by the EHD. <br /> For all three tanks, in the section Under Dispenser Containment(UDC)Monitoring, change'yes'to'no'for'UDC <br /> monitoring stops flow of product at dispenser.' <br /> For all three tanks, in the section under periodic testing, change'no'to'yes'for spill bucket testing. <br /> For all three tanks,fill the second person having responsibility section. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 121 CCR 2712(f)Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 12/5/2016 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by 1/4/2017 . This <br /> information was received late. An operator that receives an inspection report shall have 30 days to submit a written <br /> response that includes a statement documenting corrective actions taken or proposing corrective actions which will <br /> be taken. Ensure that a written response documenting corrective actions taken or proposed is submitted within 30 <br /> days of receiving an inspection report. <br /> This is a Class II violation. <br /> 209 CCR 2715(c)Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to attach all of the alarms to the August 2017 designated operator monthly <br /> inspection report and failed to check that they were responded to appropriately. The 1-8: 87 Annular sensor was <br /> missing. During the monthly inspection,the designated operator shall review the alarm history for the previous <br /> month,check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing monthly inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 215 CCR 2712(1)Failure to retain a copy of the permit to operate at the facility. <br /> A copy of the 2017 permit to operate was not on site. Immediately get a copy and retain at facility. <br /> This is a minor violation. <br /> 313 HSC 25290.1,25290.2,25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> The fuel filter in the 3/4 dispenser was observed dripping indicating a leak in the primary piping. The All primary <br /> containment for the UST system must be tight. Immediately have a properly licensed,trained, and certified <br /> contractor repair or replace the failed component under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> FA0000819 PR0231429 SCO01 12/04/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />