My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_1986-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 11:58:15 AM
Creation date
6/23/2020 6:48:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2002
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_1986-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 <br />INSTRUCTIONS FOR COMPLETING FORM „B„ <br />GENERAL INSTRUCTIONS <br />Section 2711 of Title 23, Division 3, Chapter 16, California Code of Regulations and sections 25286, 25287, and 25289 <br />of Chapter 6.7, Division 26, Health, and Safet.� Code require tank owners to appty for an UST operating permit. <br />1. One FORM "B" shall be ccmr I :fed for each tank for all NEW PERMITS, PERMIT CHANGES, REMOV- <br />ALS and/or any other TANK iN€=ORMA.TION CHANGE. <br />2. This form should be completed by either the PERMIT APPLICANT or the LOCAL AGENCY UNDER- <br />GROUND TANK INSPEC"1 0H, <br />3. Please type or print clearlya,11 requested information. <br />4. Use a hard point writing instrument, you are. making 3 copies. <br />5. Tank owners must submit a plot plan to the local agency showing the location of the USTs with respect <br />to buildings and landmarks [2711 (a)(8) CCR]. <br />6, Tank owners must submit documentation showing compliance with state financial responsibility require- <br />ments to the local agency for petroleum USTs [2711 (a)(11) CCR]. <br />TOP OF FORM: MARK ONLY ONE ITEM <br />1. Mark an (X) in the box next to the item that best describes the reason the form is being completed. <br />2. Indicate the DBA or Facility name where the tank is installed. <br />1. TANK DESCRIPTION - COMPLETE ALL ITEMS - 1F UNKNOWN - SO SPECIFY <br />A. Indicate owners tank ID # - If there is a tank number that is used by the owner to identify the tank (ex. <br />AB70789). <br />B. Indicate the name of the company that manufactured the tank (ex. ACME TANK MFG). <br />C. Indicate the year the tank was installed (ex. 1987), <br />D. Indicate the tank capacity in gallons (ex. 25,000 or 10,000 etc.). <br />11. TANK CONTENTS <br />A. 1. IF MOTOR VEHICLE FUEL, check box 1 and complete items B & C. <br />2. If not MOTOR VEHICLE FUEL, check the appropriate box in section A and complete items B & D. <br />B. Check the appropriate box. <br />C. Check the type of MOTOR VEHICLE FUEL (if box 1 is checked in A). <br />D. Print the chemical name of the hazardous substance stored in the tank and the C.A_S.#. (Chemical <br />Abstract Service number), if box 1 is NOT checked in A. <br />Ill. TANK CONSTRUCTION - MARK ONE ITEM ONLY IN BOX A, B, C & D <br />1. Check only one item in TYPE OF SYSTEM, TANK MATERIAL, INTERIOR LINING and CORROSION <br />PROTECTION. <br />2. If OTHER, print in the space provided. <br />IV. PIPING INFORMATION <br />1. Circle "A" if above ground circle „U„ if underground, and circle both if applicable. <br />2. If UNKNOWN circle; or if OTHER, print in space provided. <br />3. Indicate the LEAK DETECTION system(s) used to comply with the monitoring requirement for the piping. <br />V. TANK LEAK DETECTION <br />1. Indicate the LEAK DETECTION system(s) used to comply with the monitoring requirements for the tank. <br />VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br />1. ESTIMATED DATE LAST USED - MONTH/YEAR (January, 1988 or 01/88) <br />2. ESTIMATED QUANTITY of HAZARDOUS SUBSTANCE remaining in the tank (in Gallons). <br />3. WAS TANK FILLED WITH INERT MATERIAL? Check "Yes" or "No". <br />TANK OWNER OR AUTHORIZED REPRESENTATIVE MUST SIGN AND GATE THE FORM AS INDI- <br />CATED [see section 2711 (a)(13) CCR] <br />INSTRUCTION FOR THE LOCAL AGENCIES <br />The state underground storage tank identification number is composed of the two digit county number, the three digit <br />jurisdiction number, the six digit facility number and the six digit tank number. The county and jurisdiction numbers are <br />predetermined and can be obtained by calling the State Board (9,16) 227-4303. The facility number must be the same as <br />shown in form "A". The tank number may be assigned by the local agency, however, this number must be numerical and <br />cannot contain an alphabet. if the local agency prefers the State Board to assign the tank number, please leave it blank. <br />IT IS THE RESPONSIBILITY OF THE LOCAL .AGENCY THAT INSPECTS THE FACILITY TO VERIFY THE ACCU- <br />RACY OF THE INFORMATION. THE LOCAL AGENCY IS RESPONSIBLE FOR THE COMPLETION OF THE <br />„LOCAL AGENCY USE ONLY" INFORMATION BOX. THE LOCAL AGENCY SHOULD RETAIN THE ORIGINAL AND <br />YELLOW COPIES, THE PINK COQ' SHOULD BE RETAINED BY THE TANKNER. <br />
The URL can be used to link to this page
Your browser does not support the video tag.