Laserfiche WebLink
T 2:PREMIUM <br /> PRODUCT CODE 2 OUTPUT RELAY SETUP <br /> THERMAL COEFF : .000700 — — — — — — — _ _ _ <br /> TANK DIAMETER 96.00 2,:ti — — <br /> TANK PROFILE 4 FTS R 1 :REG <br /> FULL VOL 12000 TYPE: <br /> 72.0 INCH VOL 9999 LIQUID SENSOR SETUP STANDARD <br /> 48.0 INCH VOL 6355 — — — — — — — — — — — — <br /> NORMALLY CLOSED <br /> 24.0 INCH VOL 2505 <br /> L 1 :REG SUMP <br /> TRI—STATE (SINGLE FLOAT) IfV—TANK ALARMS f <br /> FLOAT SIZE: 4.0 IN. 8496 CATEGORY : STP SUMP ALL:HIGH WATER ALARM <br /> ALL:LOW PRODUCT ALARM j <br /> 1 WATER WARNING 1 .0 j ALL:SUDDEN LOSS ALARM <br /> HIGH WATER LIMIT: 3.0 L 2:PREM SUMP ALL:GROSS TEST FAIL <br /> TRI—STATE (SINGLE FLOAT) <br /> MAX OR LABEL VOL: 11400 CATEGORY : STP SUMP LIQUID SENSOR ALMS <br /> OVERFILL LIMIT 90% L I :FUEL ALARM 3a <br /> 10260 , L 2:FUEL ALARM <br /> HIGH PRODUCT 92% L 3:REG. ANNULAR ALL:SENSOR OUT ALARM 1 <br /> 10488 DUAL FLOAT HYDROSTATIC ALL:SHORT ALARM <br /> DELIVERY LIMIT 10% i CATEGORY ANNULAR SPACE L i :WATER ALARM <br /> 1200 L 2:WATER ALARM <br /> L 3:WATER OUT ALARM <br /> LOW PRODUCT 736 i L 4:WATER OUT ALARM <br /> LEAK ALARM LIMIT: 99 L 4:PREM ANNULAR L 3:LOW LIQUID ALARM <br /> SUDDEN LOSS LIMIT: 25 i DUAL FLOAT HYDROSTATIC L 4:LOW LIQUID ALARM <br /> TANK TILT 2.15 j CATEGORY ANNULAR SPACE <br /> R 2:PREM <br /> MANIFOLDED TANKS TYPE: <br /> Tii: NONE STANDARD <br /> NORMALLY CLOSED <br /> LEAK MIN PERIODIC: 0% <br /> 0 IN—TANK ALARMS <br /> PERIODIC TEST TYPE ALL:LEAK ALARM <br /> STANDARD ! ALL:HIGH WATER ALARM <br /> _ ALL:LOW PRODUCT ALARM <br /> PERIODIC TEST FAIL ---- ALL:SUDDEN LOSS ALARM <br /> ALARM DISABLED ALL:GROSS TEST FAIL <br /> GROSS TEST FAIL J LIQUID SENSOR ALMS <br /> ALARM DISABLED ! 1 L I :FUEL ALARM <br /> 1 L 2:FUEL ALARM <br /> PER TEST AVERAGING: OFF '° ' ALL:SENSOR OUT ALARM < <br /> ALL:SHORT ALARM <br /> TANK TEST NOTIFY: OFF L 1 :WATER ALARM <br /> L 2:WATER ALARM <br /> TNK TST SIPHON BREAKOFF j L 3:WATER OUT ALARM <br /> L 4:WATER OUT ALARM <br /> DELIVERY DELAY 1 MIN L 3:LOW LIQUID ALARM <br /> i L 4:LOW LIQUID ALARM <br /> i <br /> . z <br /> F: <br /> LEAK. TEST METHOD SOFTWARE REVISION LEVEL t <br /> — VERSION 15.05 <br /> TEST ON DATE ALL TANK SOFTWARE# 346015-100—F <br /> JAN 1. 1996 CREATED —1 98.03.25.14.58 j START TIME : DISABLED fi <br /> TEST RATE :0.20 GAL/HR NO SOFTWARE MODULE ? <br /> DURATION 2 HOURS SYSTEM FEATURES: <br /> - PERIODIC IN—TANK TESTS <br /> ANNUAL IN—TANK TESTS <br /> LEAK TEST REPORT FORMAT <br /> NORMAL <br /> i <br /> �... <br />