My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 12:38:04 PM
Creation date
6/23/2020 6:48:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
440
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALTON <br />ENGINEERING, INC. <br />QUIK STOP 121 - 1196 W. LOUISE, MANTECA, CA 95336 03/11/98 09:37 <br />TANK HOLDDOWN/BUOYANCY CALCULATION - 12,000 GAL. <XERX-12K.WK1> <br />THIS CALCULATION IS FOR XERXES TANKS, AS DESCRIBED BELOW: <br />CAPACITY 11527 GALLONS WEIGHT 4650 LBS. <br />DIAMETER 8.00 FEET SUMPS 2 <br />LENGTH 37.04 FEET <br />TANK SLAB THICKNESS 0.67 FT. <br />BURY DEPTH (TOP OF SLAB) 4.00 FT, <br />ASSUME TANK AND BACKFILL COMPLETELY SUBMERGED, TO BOTTOM OF SLAB: <br />SUBMERGED WGT OF BACKFILL : 60.00 LBS/C.F. (PCF) <br />UNSUBMERGED WGT OF CONC. = 150.00 PCF <br />WATER = 7,48 GALS./C.F. <br />WATER : 62.40 PCF <br />1. OVERBURDEN ABOVE THE TANK CAN BE CALCULATED USING THE FOLLOWING <br />FORMULA (PER PEI/RP 100-94): <br />((H/3)(B1 + B2 + SgRt B1=B2)) - ((V/2) + M) <br />D = TANK DIAMETER <br />d : BURIAL DEPTH (to BOTTOM of SLAB) : 3.33 FT, <br />H = (D/2) + d = 7,33 FT. <br />L = TANK LENGTH <br />B1 = SLAB AREA = (L+4)=(D+3) : 451.44 SQ.FT. <br />B2 : REFLECTED TANK AREA (D=(L-D)+(D/2*D/2*Pi) = 282.59 SQ.FT. <br />V = TANK DSPLMNT. = Pi((rr*L-2r)+(4/3=rrr)) = 1727.79 C.F. <br />M = VOIDS IN OVERBURDEN : 48" DIAM. SUMPS = 2 SUMP <br />= Pi=(4.0'/2)(4.0'/2) 3.33 FT, t # = 83.78 C.F. <br />THEREFORE OVERBURDEN ABOVE TANK WOULD BE EQUAL TO: <br />H/3 B1+B2 SgRtBl*B2 (V/2)+M <br />2.44 734.03 357.17 947,67 = 1719.69 C.F. <br />1719.69 C.F. t 60.00 PCF : 103182 LBS. <br />2. CONCRETE SLAB = B1 a SLAB THICKNESS s CONC. WGT. = 45144 LBS. <br />3. TANK WEIGHT (PER MANUFACTURER) = 4650 LBS. <br />4. TANK TOP ANCILLARY EQUIPMENT : 1250 LBS. <br />TOTAL UPLIFT FORCE (UF) = (V+M) $ WATER.WGT.= 113042 LBS. <br />TOTAL RESISTANT FORCE (RF) _ (ITEMS 1.-4.) = 154226 LBS. <br />EXCESS RESIST FORCE RF -UF : 41184 LBS.: 20.6 TONS <br />RF MORE THAN UF, THEREFORE, BOLDDOWNS NOT REQUIRED AT 48 " MIN, BURY DEPTH. <br />SAFETY FACTORY : RF/UF : 1.36 (DOES NOT INCLUDE FRICTION FACTORS, <br />NOR REDUCTION FOR WET INTERSTITIAL SPACE, WHICH INCREASE MARGIN). <br />-o00- <br />843 Riske Lane, West Sacramento, CA 95691 (916) 372-1888 - Fax 373-1172 <br />Moilina Address: DO Box 1025, West Sacramento, CA 95691 <br />
The URL can be used to link to this page
Your browser does not support the video tag.