My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 12:38:04 PM
Creation date
6/23/2020 6:48:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
440
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.6.1 Piping Layout <br />Advance planning of the piping lay- <br />outisessential. [twill make servicing <br />the system easier and can reduce the <br />quantities of material required. <br />1. Using the shortest practical route, <br />run the pipe in a single trench from <br />the tanks to the vent risers. <br />2. Pipe should run parallel to the <br />tanks and dispensers. <br />3. Avoid piping across the tanks. <br />1.6.2 Trenching and backfilling <br />Proper construction of trenches is <br />important. They should be wide and <br />deep enough to accommodate the <br />piping and backfill material. See <br />Table 1.6.1 for recommended mini- <br />mum burial depths. <br />1. Typically, all piping should slope <br />at least 1/8 inch (3mm) per foot <br />toward the tank. Support pipe <br />properly to prevent traps or sumps. <br />v <br />W..3^ <br />FIBERGLASS, . <br />2. The piping should be separated by <br />a distance of at least four to six <br />inches (100-1 50mm); the pipe and <br />trench wall should be separated <br />by at least six inches (150mm). <br />See Figure 1.6.3. For double-wall <br />secondary containment piping in- <br />stallations, refer to Part Two, Sec - <br />TABLE 1.6.1 <br />RECOMMENDED MINIMUM BURIAL DEPTHS BASED ON SOIL MODULUS OF 1,000 PSI OR HIGHER <br />(Refer to ASTM D3839 or AWWA C950 for Method/Theory) <br />10 <br />- <br />Min. <br />Amount of Sand <br />Pipe Size <br />Surface Condition <br />Minimum <br />or Pea Gravel above <br />Burial <br />Depth <br />the <br />Top of the Pipe <br />(in.) O,:::::.: <br />(in.) <br />(mm) <br />(in.) <br />2 <br />Un paved P <br />17 <br />12 <br />v . 4 <br />Pa ed nunasphalt <br />100mm <br />12 <br />Paved, min. 4" <br />(100mm) concrete <br />9 <br />22 <br />5 <br />127" <br />3 75 <br />Unpaved <br />20 '`:`:' <br />508 <br />14 <br />35& <br />Paved, min. 4") <br />100mm as <br />( asphalt <br />13 <br />Paved, min. 4 <br />100mm concrete. <br /><>...27:' <br />7 <br />t <br />4O( <br />Unpaved <br />20 <br />SOS;°:> <br />14 <br />356 <br />Paved, min. 4") <br />asphalt halt <br />( P <br />14 <br />356 <br />10 <br />24 <br />Paved, min. 4 <br />(100mm) concrete <br />11279 <br />7 <br />17$ <br />10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.