My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 12:38:04 PM
Creation date
6/23/2020 6:48:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
440
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Information <br /> Facility Name: Quik Stop Market#121 Bldg.No.: <br /> Site Address: 1196 W. Louise Ave. City: Manteca Zip: 95336 <br /> Facility Contact Person: Michael Karyelot Contact Phone No.: 510 )657-8500 <br /> Make/Model of Monitoring System: Gilbarco EMC Date of Testing/Servicing: 5 /23 /05 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appro Hate boxes to indicates ecitic a ui ment inspected/serviced: <br /> Tank ID: 87 Tank ID: 91 <br /> In-Tank Gauging Probe. Model: Hoag Probe 0 In-Tank Gauging Probe. Model: Mag Probe <br /> Annular Space or Vault Sensor. Model: PA002593000002 0 Annular Space or Vault Sensor. Model: PA002593000002 <br /> ■ Piping Sump/Trench Sensor(s). Model: PA002592000010 N Piping Sump/Trench Sensor(s). Model: PA002592000010 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ■ Mechanical Line Leak Detector. Model: FE Petro STP-MLD 0 Mechanical Line Leak Detector. Model: FE Petro STP-MLD <br /> ❑ Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment a and model in Section Eon Page 2). ❑Other(s2ecify a ui ment type and model in Section E on P e 2). <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment a and model in Section E on P2ge 2). ❑Other(specify equipment a and model in Section E on P e 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). 0 Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). 0 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). ❑ Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s). ❑Dispenser Containment Floats and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ®System set-upm history report <br /> Technician Name(print): Phillip Klingman Signature:?__ <br /> Certification No.: 006-05-0809 License.No.: 617238 <br /> Testing Company Name: Walton Engineering,Inc. Phone No.:( 916 ) 373-1152 <br /> Site Address: 3900 Commerce Drive,West Sacramento,CA 95691 Date of Testing/Servicing: 5 / 23 / 05 <br /> UN-036-1/4 Page 1 of 3 Rev.06/04/01 <br /> CUPA: San Joaquin County Enviro Health WALTON <br /> INSPECTOR: Ray Von Flue ENGINEERING, INC. <br /> www.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.