Laserfiche WebLink
SY3WEM SET—UP REPORTOPage2) <br />T 2:Premium_Unlead <br />PRODUCT CODE B <br />THERMAL COEFF :.000700 <br />TANK DIAMETER 96.00 <br />TANK PROFILE 4 PTS <br />FULL VOL 12000 <br />72.0 INCH VOL 9999 <br />48.0 INCH VOL 6355 <br />24.0 INCH VOL 2505 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING <br />1.0 <br />HIGH WATER LIMIT: <br />2.0 <br />MAX OR LABEL VOL: <br />12000 <br />OVERFILL LIMIT <br />90 <br />10800 <br />HIGH PRODUCT <br />95% <br />FP FL <br />11400 <br />DELIVERY LIMIT <br />10% <br />01 <br />1200 <br />LOW PRODUCT 736 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 2.15 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />T#: NONE <br />LEAK. MIN PERIODIC: 0% <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY : 1 MIN <br />PUMP THRESHOLD : 10.00% <br />V 2006 Watton Engineering, Inc. <br />LEAK TEST METHOD <br />TEST ON DATE ALL TANK <br />FEB 6, 2007 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L 1:87 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 2:91 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUM13 <br />L 3:87 ANNULAR <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />L 4:91 ANNULAR <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />OUTPUT RELAY SETUP <br />R 1:87 STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 1 <br />LIQUID SENSOR ALMS <br />L 1:FUEL ALARM <br />L 1:SENSOR OUT ALARM <br />L 1:SHORT ALARM <br />ISD SITE r;TARMS <br />ISD GROSS PRES FAIL <br />ISP DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:91 STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 2 <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />IBI? DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />SMARTSENSOR SETUP <br />s 1:DISP 1-2 AFM <br />CATEGORY AIR FLOW METER <br />s 2:DISP 3-4 AFM <br />CATEGORY AIR FLOW METER <br />s 3:DISP 5-6 AFM <br />CATEGORY AIR FLOW METER <br />s 4:VAPOR PRESSURE <br />CATEGORY VAPOR PRESSURE <br />EVR./ISD SETUP <br />EVR TYPE: VACUUM ASSIST <br />VACUUM ASSIST TYPE <br />HEALY VAC. <br />NOZZLE A.L RANGE <br />MAX: 1.15 MIN: Y.-913 <br />VAPOR PROCESSOR TYPE <br />NO VAPOR PROCESSOR <br />ANALYSIS TIMES <br />TIME: 10:00 AM <br />DELAY MINUTES: 1 <br />ACCEPT HIGH ORVR: <br />DISABLED <br />ISD <br />HOSE TABLE <br />ID <br />FP FL <br />HL <br />AA <br />RR <br />01 <br />01 Ol <br />02 <br />01 <br />UU <br />02 <br />02 02 <br />02 <br />01 <br />UU <br />03 <br />03 03 <br />02 <br />02 <br />UU <br />04 <br />04 04 <br />02 <br />02 <br />UU <br />05 <br />05 05 <br />02 <br />03 <br />UU <br />06 <br />06 06 <br />02 <br />03 <br />UU <br />