Laserfiche WebLink
SY EM SET-UP REPORT Page 1) <br />SYSTEM ­-ETUP cot, i iuiiICtil'1!?IVS SETUP 11.1 -'PHP:}: ET'UP <br />JUN IS. 2008 8:37 All. - <br />SYESTEM UNITS <br />U.S. <br />SYSTEM LHN61JfiC E <br />ENGL 1 SH <br />SYSTEM 11HTE T] ME FORT IH'P <br />MON DD `;''.";'`;' HH:M1'1:S S 41 <br />GUIK STOP 1 1 <br />1196 W.LOUISE AVE. <br />MANTECA, CA. 95336 <br />209-239--295? <br />SHIFT TIME 1 DISHBLED <br />SHIFT TIME DISABLED <br />SHIFT TIME 3 DISHBLED <br />SHIFT TIME 4 DISHBLED <br />TANK PER TST NEEDED WRN <br />DISHBLED <br />TANK ANN TST NEEDED WRN <br />DISABLED <br />LINE RE-ENhBLE METHOD <br />PASS LINE TEST <br />LINE PER TST NEEDED WRN <br />DISABLED <br />LINE ANN TST NEEDED WRN <br />DISABLED <br />PRINT TC VOLUMES <br />ENABLED <br />TEMP COMPENSATION <br />VALUE (DEG F ;: 60.0 <br />STICK HEIGHT OFFSET <br />DISABLED <br />ULLHGE: 90% <br />H -PROTOCOL DATA FORMAT <br />HEIGHT <br />DAYLIGHT SH%,.ING TIME <br />ENABLED <br />START DATE <br />APR WEEK 1 SUN <br />START TIME <br />2:00 AM <br />END DATE <br />OCT WEEK 6 SUN <br />END TIME <br />2:00 AM <br />RE -DIRECT Lt;C'HL PRII-IT'OUT <br />DISABLED <br />EURO PROTOC'O'L PREFI?; <br />S <br />© 2006 Walton Engineering, Inc. <br />PORI' SETT I NGS: <br />CONN BOARD I (RS •-'23 2 ) <br />BHUD RATE 9600 <br />PARITY NONE <br />STOP BIT 2 STOP <br />DATA LENGTH: 8 DATA <br />RS -232 SECURITY <br />CODE DISABLED <br />COMM BOARD 2, t.RS-'232 <br />BAUD RATE 1200 <br />PARITY ODtr <br />STOP BIT 1 STOP <br />DATA LENG'T'H: 7 DHTH <br />RS -12,32 SE('LIRIT;' <br />CODE : DISABLED <br />COMM BOARD : 3 (EDIM ? <br />RS -232 SECURITY <br />CODE : DISABLED <br />COMM BOARD 5 (S-SHT i <br />BAUD RATE 9600 <br />PFR I T',' NONE <br />STOP BIT 1 STOP <br />DATA LENGTH: 8 DATA <br />RS -232 SECUR I T'i <br />CODE DISABLED <br />DTR NORMAL TATE: HIGH <br />AUTO TRANSMIT SETTINGS: <br />AUTO LEAK. ALARM LIMIT <br />DISABLED <br />AUTO HIGH WATER LIMIT <br />DISABLED <br />AUTO OVERFILL LIMIT <br />DISABLED <br />AUTO LOW PRuf1UC.1. <br />DISABLED <br />AUTO THEFT LIMIT <br />DISABLED <br />AUTO DELIVERY 'START <br />DISABLED <br />AUTO DELIVERY END <br />DISABLED <br />AUTO EXTERNAL INPUT ON <br />DISABLED <br />AUTO EXTERNAL INPUT OFF <br />DISABLED <br />AUTO} SENSOR FUEL ALARM <br />Lr 1 SHBLED <br />AUTO SENS,:iR WATER ALARM <br />DISABLED <br />AUTO SENSOR OUT ALARM <br />DISHBLED <br />T 1 : Ur leaded <br />PRODUCT CODE <br />H <br />THERMAL COEFF <br />:.0001700 <br />TANK DIAMETER <br />96.00 <br />TANK PROFILE <br />4 FTS <br />FULL '. c:L <br />12000 <br />72.0 1 NCH "1 <br />9999 <br />48.0 I NCH '16355 <br />24.0 INCH VOL <br />2505 <br />FLOAT SIZE: 4.0 IN. <br />MATER WARNING, 1.0 <br />HIGH WATER LIMIT: 2.0 <br />MA': OR LABEL VOL: 12000 <br />OVERFILL LIMIT' 90% <br />10800 <br />HIGH PRODUCT 95`6 <br />11400 <br />DELIVER)'' LIMIT 10% <br />1200 <br />LOW PRODUCT 736 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 2.38 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MHNIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PER 1 OL,1 C : 0`a <br />0 <br />PERIODIC' TEST TYPE <br />STANDARD <br />PERIODIC TEEN' FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM D I SHBLED <br />PER TEST HVERHG I N1,: OFF <br />TANK TEST NOT I F'•i' : OFF <br />TNK TST SIPHON BREAE : ;IFF <br />DELIVERY DELA`,' I M I N <br />PUMP THRESHOLD 10.00a<: <br />