Laserfiche WebLink
Ak <br /> SY EM SET-UP REPOR (Paget) <br /> T 'DUCTniuD-Unlead OUTPUT RELAY SETUP <br /> PRODUCT CODE B <br /> THERMAL OOEFF : .000700 E+VR-"ISL' SETUP - - - - - - - - - - <br /> TANK DIAMETER 96.00 R 1 :87 STP <br /> PROFILE 4 PTS <br /> FULL VOL 12000 TYPE: <br /> 72.0 INCH VOL 9999 EVP TYPE: VACUUM ASSIST STANDARD <br /> 48.0 INCH VOL 6355 VAC:UUh1 ASSIST TYPE NORPIALL'Y CLOSED <br /> 24.0 INCH VOL 2505 HEALY VAC <br /> TANK 0: ! <br /> NUZZLE A;'L RANGE <br /> FLOAT SIZE: 4.0 IN. MAX: 1 .15 MIN: 0.95 <br /> LIQUID SEIJSOR ALMS <br /> WATER WARNING 1 .0 VAPOR PROCESSOR TYPE L 1 :FUEL ALARM <br /> HIGH i4ATER LIMIT: 2.0 NO VAPOR PROCESSOR L I :SENSOR OUT ALHRI-I <br /> L 1 :SHORT ALARM <br /> MAX OR LABEL VOL: 12000 <br /> OVERFILL LIMIT 90% ANALYSIS TIMES ISD SITE ALARMS <br /> 10800 TIME: 10:00 AM ISD GROSS PRIES FAIL <br /> HIGH PRODUCT 95% DELAY MINUTES: 1 ISD DEGRD PRES FHIL <br /> 11400 ISD VAPOR LEAP: FAIL <br /> DELIVERY LIMIT 1015 IND HOSE ALARMS <br /> ACCEPT HIGH ORVR: <br /> DISABLED ALL:GROSS C:OLLEC'T FAIL <br /> LOW PRODUCT 736 ALL:DEGRD COLLECT FAIL <br /> LEAK ALARM LIMIT: 99 ISD HOSE TABLE ALL:FLOW COLLECT FAIL <br /> SUDDEN LOSS LIMIT: 99 ID FP FL HL AH RR R x91 STP <br /> TANK TILT 2.15 -------------------------- TYPE:PROBE OFFSET 0.00 01 01 UI 02 01 UU <br /> 02 02 02 02 01 UU STANDARD <br /> 03 03 03 02 02 UU NORMALLY CLOSED <br /> SIPHON MANIFOLDED TANKS 04 04 04 02 02 UU <br /> T#: NONE 05 05 05 02 03 UU TANK #: <br /> LINE MANIFOLDED TANKS 06 06 06 02 03 UU <br /> T#: NONE <br /> LIQUID SENSOR ALhIS <br /> ISD AIRFLOW METER MAF L 2:FUEL ALARM <br /> LEAK MIN PERIODIC: 0% ID SERIAL NUM LABEL L 2:SENSOR OUT ALARM <br /> 0 ------------------------ L 2:SHORT ALARM <br /> PERIODIC TEST TYPE 1 :35209 DISP 1-2 A ISD SITE HLr;RtiS <br /> STANDARD 2 22908 DISP 3-4 A <br /> 3 9336 DISP 5-6 A ISD GROSS PRES FAIL <br /> PERIODIC TEST FAIL ISD DEGRD PRES FAIL <br /> ALARM DISABLED ISD VAPOR LEAK FAIL <br /> ISD FUEL GR 4DE HOSE MAP' ISD HOSE ALARMS <br /> GROSS TEST FAIL 1 2 3 4 <br /> ALARM DISABLED FP MHH MHH MHH MHH AA HLL:GROSS COLLECT FAIL <br /> ------------------------ ALL:DEGRD COLLECT FAIL <br /> PER TEST AVERAGING: OFF 01 401 901 501 U U I ALL:FLOW COLLECT FAIL <br /> 02 402 902 502 U U i SHARTSENSOR SETUP <br /> TANK TEST NOTIFY: OFF 03 403 903 503 U U 2 - - - - - - - - -. - - - <br /> 04 404 904 504 U U 2 <br /> TNK TST SIPHON BREAKOFF 05 405 905 505 U U 3 5 1 :DISP 1-2 AFM <br /> DELIVERY DELAY l MIN 06 406 906 506 U U 3 CATEGORY AIR FLOW METER <br /> PUMP THRESHOLD 10.00% s 2:DISP 3-4 AFM <br /> LABEL TABLECATEGORY AI R FLOI,J METER <br /> LIQUID SEMS R SETUP ------------ <br /> - - - - - - - - - - - - 1 : UNASSIGNED 5 3:DISP 5-6 AFM <br /> 2: BLEND3 CATEGORY AIR FLO6I METER <br /> L 1 :87 STP SUMP 3: REGULAR <br /> TRI-STATE (SINGLE FLOAT) 4: MID GRADE s 4:VdfAPOR PRESSURE <br /> CATEGORY : STP SUMP 5: PREMIUM CATEGORY VAPOR PRESSURE <br /> 6: GOLD <br /> 7: BRONZE <br /> L 2:91 STP SUMP 8: SILVER AUTO DIAL TIME SETUP: <br /> TRI-STATE (SINGLE FLOAT) 9: BLEND2 <br /> CATEGORY : STP SUMP 10: BLEND4 <br /> D 1 :RADIENT <br /> RS-23'2 END OF MESSAGE DIAL ON DATE <br /> L 3:87 ANNULAR DISABLED APR 23. 2009 <br /> DUAL POINT HYDROSTATIC: DIAL TIME : DISABLED <br /> CATEGORY : ANNULAR SPACE AUTO DIAL ALARM SETUP RECEIVER REPORTS: <br /> D 1 :RADIENT <br /> L 4:91 ANNULAR - NO ALARM ASSIGNMENTS - <br /> DUAL POINT HYDROSTATIC <br /> CATEGORY : ANNULAR SPACE <br /> O 2011 Walton Engineering,Inc. <br />