My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2006-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2024 11:04:03 AM
Creation date
6/23/2020 6:48:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2011
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2006-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sj„gov.orci/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 06/06/11 <br /> Facility Address: 1196 W. Louise Ave, Stockton Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> This is a routine and monitoring certification inspection. The following are violations observed: <br /> #4,13,21,27 <br /> 4. (Repeat Violation) Financial responsibility documents have not been submitted to the EHD. Current <br /> financial responsibility documents are required to be submitted annually. Complete and submit a copy <br /> of the financial responsibility by July 8, 2011. <br /> 13. (M1) (Repeat Violation) The 91-octane Bravo box float and chain in Dispenser#6 UDC sump failed <br /> to stop the flow of product at the dispenser when tested. All monitoring equipment shall be maintained <br /> to activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a <br /> leak. Observed service technician adjusted the chain and verified functionality. <br /> 21. Liquid was observed in the 87 and 91 octane fill sumps. If water could enter into the secondary <br /> containment by precipitation or infiltration, it must be removed and disposed of properly. Immediately <br /> remove this liquid, make a hazardous waste determination per Title 22 hazardous waste regulations, <br /> and manage it accordingly. Ensure that the sumps are maintained free of liquid. Observed service <br /> technician disposed the liquid from the sumps to the hazardous waste container on site. <br /> 27. The monitoring panel frozen after testing for failsafe; therefore the monitoring system does not meet <br /> the requirements for annual line tightness testing exemption. Annual line tightness testing is required <br /> unless the UST system is equipped with the following: <br /> 1. A continuous monitoring system that either activates an audible and visual alarm or stops the flow <br /> of product at the dispenser when it detects a leak <br /> 2. A monitoring system that shuts down the pump or stops the flow of product at the dispenser when <br /> it detects a leak <br /> 3. A monitoring system for piping other than that in UDC sumps (tank top sumps, transition vents, <br /> etc.) is failsafe and shuts down pump when a leak is detected <br /> Immediately schedule this test and provide 48 hours notification to the EHD, or reprogram/repair the <br /> monitoring panel to satisfy the annual line tightness testing requirement. Observed technician replaced <br /> the board and reprogrammed the panel to meet failsafe, performed cold start, and verified functionality <br /> of the monitoring system as an emergency repair. Submit a permit application to EHD within one <br /> business day of the repair. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by: July 8, 2011 <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD I ecto. Received By: Title: <br /> EH 23-0 03 8/10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.