My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2024 1:05:50 PM
Creation date
6/23/2020 6:48:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
310
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />WALTON <br />tti <br />E <br />Overi-ill Prevention Inspection - OPW 61 and 71 Series Devices <br />Facility: Quik S�#121 <br />OP W Overfill Model Number: LlSO _ <br />Part 1 - Proper Height Settinp- Calculation -) Ii I <br />Part 2 - Device Certification Criteria Evaluation <br />Does the overfill prevention device meet the 9570 <br />requirement? <br />Yes <br />Tank I <br />Tank 2 <br />Tank 3 <br />Tank 4 <br />Maximum Tank Volume Per: <br />A Gallons <br />11527 <br />11527 <br />more than the fill riser? (J must be 6.5" or more than E) <br />Yes <br />Max shut off requirement for flapper is 95% <br />B 95% <br />.95 <br />95 <br />Multiply Max tank volume by 951'X <br />C Gallons <br />10950 <br />10950 <br />Yes <br />Use tank chart or ATG to determine height of <br />movement, weaken!ET due to wear and corrosion) <br />calculated volume <br />—or <br />D Inches <br />801/2" <br />80 1/2" <br />Measure top of fill riser threads, face ,,—al <br />— <br />adapter <br />E Inches <br />38 3/4" <br />40 3/4" <br />Tank diameter (From Tank Chart) <br />F Inches <br />89 3/4" <br />89 3/4" <br />Upper Tube in Tank (G) F -D = G <br />G Inches <br />9 3/4" <br />9 3/4" <br />Subtract 2" from upper tube in tank G-2"= K <br />K Inches <br />7 3/4" <br />7 3/4" <br />Calculated minimum upper tube length (1) <br />L - <br />K+E=l <br />1 Inches <br />46" <br />48" <br />Actual measured upper tube length (Without <br />till a Japter) (J) <br />j Inches <br />46 3/4" <br />48 1/4" <br />Part 2 - Device Certification Criteria Evaluation <br />Does the overfill prevention device meet the 9570 <br />requirement? <br />Yes <br />Yes <br />I Drop Tube Testing PASS / FAIL <br />Is the actual measured upper tube length 6.5 inches or <br />more than the fill riser? (J must be 6.5" or more than E) <br />Yes <br />Yes <br />Does the overfill prevention device function as required? <br />(Inspect the device for damage, contamination, freedom of <br />Yes <br />Yes <br />movement, weaken!ET due to wear and corrosion) <br />M"IMIN =,of 14111 <br />I Drop Tube Testing PASS / FAIL <br />ZMEMEW <br />Technician certifies that the device is operationally compliant. <br />Date: 9/24/18 <br />