MONITORING SYSTEM CERTIFICATION° �� "5"" ,:y `mxw <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 (% Y'{ 3 i 2017 <br />CERTIFICATION /TEST DATE: May 25, 2017 <br />A1. FACILITY <br />Name <br />Name <br />Quik Stop Market #121 <br />Address <br />1196 W. Louise Avenue, Manteca, CA 95336 <br />Phone # <br />510-657-8500 <br />Contact <br />Roger Batra <br />A3. CUPA <br />Name <br />San Joaquin County Environmental Health <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Notified <br />May 10, 2017 <br />Inspector <br />Aaron Hang <br />Phone # <br />209-468-3442 <br />A2. OWNER L -Iv V InUIViV�;e.IN I,'�L r11 <br />Name Quik Stop Markets, Inc. 1.)FRARTNIENT <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 <br />Contact Debbie Markovich <br />A4. TESTING CONTRACTOR <br />Name <br />Walton Engineering, Inc. <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Lic # <br />617238 A, B, Haz <br />Contact <br />Veronica Freitas <br />Phone # <br />916-373-1166 <br />B. <br />INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />B1: TANKS <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Gasoline -91 <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />• <br />Annular Space or Vault Sensor <br />Model: 0794380-303 <br />Annular Space or Vault Sensor <br />Model: 0794380303 <br />• <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />0 <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />Mechanical Line Leak Detector <br />Model: FE Petro STP -MLD <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />Tank <br />#3 (Product): <br />Tank #4 (Product): _ <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />B2: <br />DISPENSERS/UDC's <br />Dispenser # : 1-2 <br />Dispenser #: 3-4 <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />Shear Valves <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 5-6 <br />Dispenser # : <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />Shear Valves <br />❑ <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # : <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Shear Valves <br />❑ <br />Shear Valves <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing th <br />layout of monitoring equipment. For any equipment capable of generating such reports, 1 have also attached a copy of the report; (check all that apply <br />■ System set-up ■ Alarm History Report <br />y <br />WALTON <br />Signature: /_) %� �"` ��- ENGINEERING, INC. <br />Technician / Cert #: Anthony Reyes 645115 8293772 Date: May 25, 2017 <br />