Laserfiche WebLink
Adsk <br />r- --I <br />lqw <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www-siqov.or_q/2hd <br />_Unddraround Storage TankPt"Inspection ReportM <br />99 PIP <br />Facility Name: <br />Facility Address: <br />Date: <br />Date: <br />t <br />QUIK STOP MARKET #2121 <br />1196 W LOUISE AVE, MANTECA <br />11 <br />y 25, 2017 <br />IONS, <br />SUMMARY OF VIOLATIONS <br />(CLASS 1. CLASS EI, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training for Kiran Kaur and Sue Kaur was last performed on 4/4/16. The designated <br />operator shall train facility employees for which he or she is responsible in the proper operation and maintenance of <br />the LIST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the LIST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a repeat violation, Class 11. <br />315 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the 87, and 91 STP sump . If water could enter into the secondary containment by <br />precipitation or infiltration, it must be removed and disposed of properly. The service technician removed <br />approximately 3 cups of liquid from the 87 and 91 STP sumps. Ensure that all sumps and annular spaces are <br />maintained free of liquid. <br />This was corrected on site. <br />This is a repeat violation, Class 11. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 6/24/17 . <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following LIST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHUS CURRENT HOURLY RATE. <br />Received by: Date: May 25, 2017 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />AARON HANG, EFIS Trainee <br />(209) 468-3453 <br />Sue Kaur, Manager <br />Page 4 of 4 <br />