My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1580
>
2300 - Underground Storage Tank Program
>
PR0231476
>
COMPLIANCE INFO_2000-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 12:56:33 PM
Creation date
6/23/2020 6:49:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2006
RECORD_ID
PR0231476
PE
2361
FACILITY_ID
FA0000684
FACILITY_NAME
QUIK STOP MARKET #3125
STREET_NUMBER
1580
Direction
W
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
259-090-21
CURRENT_STATUS
01
SITE_LOCATION
1580 W MAIN ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231476_1580 W MAIN_2000-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIED PROGRAM CONSOLIDATED FO I t �'; <br /> l (1-1 <br /> ) TANKS <br /> UNDERGROUND STORAGE TANKS - TANK 1 ��- 1D°� <br /> (two p es p r talnk) <br /> Page If of 7 <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 FACILITY ID: 1 <br /> Quik Stop Market#125 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> '11-TANK DESCRIPTIQNcalllarll+ t � lC� 51 #01it 1t <br /> 1-ST Stet trOludintutidin�s enc!landmarks shelf be suhmfted tt�the loll <br /> , . ., <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> Ad/`T 7&0-2 Xerxes If"Yes",complete one page for each compartment. <br /> DATE INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 1985/March 10,000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> Ii,�1'ANK�ONTOW <br /> R� <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ®1. MOTOR VEHICLE FUEL ❑1a. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) ®1b. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑4. GASOHOL [199.OTHER_ <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> [14. HAZARDOUS WASTE Unleaded Gasoline Premium, 92 Octane 8006-61-9 <br /> (Includes Used Oil) <br /> ❑95.UNKNOWN <br /> )II `TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3.SINGLE WALL WITH [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT [199. OTHER_ <br /> TANK MATERIAL-primary tank [:11. BARE STEEL [13. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ®8. FRP COMPATIBLE W/ ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) 100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE [195. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL [14.STEEL CLAD W/FIBERGLASS ®8. FRP COMPATIBLE [199.OTHER <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> [15. CONCRETE ❑10.COATED STEEL <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING [195.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ®1 MANUFACTURED CATHODIC❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> only) <br /> (Check all ®1 SPILL CONTAINMENT 1998 ❑1 ALARM ®3 FILL TUBE SHUT OFF VALVE; 99.3 <br /> that apply) - <br /> ®2 DROP TUBE 1998 ❑2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1985 <br /> "-'--)Y 'LEA <br /> KAETECTICHw (A de dptlon 0 stye:ri rdtorine proa )s j suwritaed to#ne l'cait agency.) wa <br /> IF SINGLE WALL TANK Checkall that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> [:13 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> +(SIR) BIENNIAL TANK TESTING ❑99 OTHER - <br /> 0-0 <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> REMAINING <br /> UPCF (1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.