My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1580
>
2300 - Underground Storage Tank Program
>
PR0231476
>
COMPLIANCE INFO_2007-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 12:59:20 PM
Creation date
6/23/2020 6:49:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2010
RECORD_ID
PR0231476
PE
2361
FACILITY_ID
FA0000684
FACILITY_NAME
QUIK STOP MARKET #3125
STREET_NUMBER
1580
Direction
W
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
259-090-21
CURRENT_STATUS
01
SITE_LOCATION
1580 W MAIN ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231476_1580 W MAIN_2007-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
313
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK ANNULAR TESTING <br />Test Method By: • Manufacturer O Industry Standard O Professional Engr. O Other (see below) <br />Test Method Uses: O Pressure 0 Vacuum o Hydrostatic o Other (see below) <br />Measuring Equipment Used: Vacuum Gauge (range 0 to 30 inches Hg) <br />Dascrintion Tank #1 Tank #2 Tank #3 <br />Product stored <br />Gasoline - 87 <br />Gasoline - 91 <br />Diesel <br />Tank manufacturer <br />Xerxes <br />Xerxes <br />Xerxes <br />Tank material <br />FRP <br />FRP <br />FRP <br />Tank capacity (US gallons) <br />10,000 <br />10,000 <br />8,000 <br />Is this a multi -compartment tank? <br />No <br />No <br />No <br />Dry or Brine filled annular? <br />Dry <br />Dry <br />Dry <br />Monitoring system show normal annular? <br />Yes <br />Yes <br />Yes <br />Is water table above tank bottom? <br />Unknown <br />Unknown <br />Unknown <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Wait time for vacuum to stabilize (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Test start time <br />10:04 AM <br />10:20 AM <br />10:34 AM <br />Initial vacuum (inches Hg) <br />10.0 <br />10.0 <br />10.0 <br />Test end time <br />11:04 AM <br />11:20 AM <br />11:34 AM <br />Final vacuum (inches Hg) <br />9.0 <br />9.0 <br />10.0 <br />Test duration (hr:min) <br />1:00 <br />1:00 <br />1:00 <br />Change in vacuum (inches Hg) <br />1.0 <br />1.0 <br />0.0 <br />Pass/Fail threshold (inches Hg / hour) <br />2.0 <br />2.0 <br />2.0 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Comments: <br />© 2006 Walton Engineering, Inc. <br />