My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1580
>
2300 - Underground Storage Tank Program
>
PR0231476
>
COMPLIANCE INFO_2007-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 12:59:20 PM
Creation date
6/23/2020 6:49:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2010
RECORD_ID
PR0231476
PE
2361
FACILITY_ID
FA0000684
FACILITY_NAME
QUIK STOP MARKET #3125
STREET_NUMBER
1580
Direction
W
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
259-090-21
CURRENT_STATUS
01
SITE_LOCATION
1580 W MAIN ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231476_1580 W MAIN_2007-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
313
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL frILL CONTAINER TEV REPORT <br /> TEST DATE: June 25, 2010 <br /> Al. FACILITY A2. OWNER <br /> Name Quik Stop Market#125 Name Quik Stop Markets, Inc. <br /> Address 1580 W.Main Street,Ripon,CA 95366 Address 4567 Enterprise Street,Fremont,CA 94538 <br /> Phone# 510-657-8500 Phone# 510-657-8500 <br /> Contact Michael Karvelot Contact Michael Karvelot <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E.Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified June 18,2010 Lic# 617238 A,B, Haz <br /> Inspector Thuy Tran Contact Richard Walton <br /> Phone# 209-468-8257 Phone# 916-825-3203 <br /> K. SPILL CONTAINER TEST RESULTS <br /> Measuring Equipment Used: Caldwell System 2001 /Walton Engineering (Level Change Indicator) <br /> Tank Number 1 2 3 <br /> Product contained Gasoline-87 Gasoline-91 Diesel <br /> Spill container capacity (US gallons) 5 5 5 <br /> Spill container manufacturer OPW OPW OPW <br /> Spill container depth (inches) 12.50 12.50 13.00 <br /> Is the spill container located in a sump? Yes Yes Yes <br /> Does sump have a liquid sensor installed? No No No <br /> Condition of spill container prior to testing Dry Dry Dry <br /> Portion of spill container tested Entire Entire Entire <br /> Depth of water level from bottom (inches) 11.00 11.00 11.50 <br /> Wait time for water level to stabilize (hr:min) 0:10 0:10 0:10 <br /> Test start time 9:35 9:35 10:21 <br /> Test end time 10:05 10:05 10:51 <br /> Test duration (hr:min) 0:30 0:30 0:30 <br /> Change in water level (±0.000 inches) 0.000 0.000 0.000 <br /> Pass/Fail threshold (0.005 inches/'/:Hr.) 0.005 0.005 0.005 <br /> TEST RESULT PASS PASS PASS <br /> L. COMMENTS: <br /> Replaced the OPW fill cap on the 91 tank. <br /> WALTON <br /> Signature: Ole 01 <br /> ENGINEERING,INC, <br /> Technician: Jessie Wadkins/B35391 5307886-UT Date: ,June 25, 2010 <br /> ©2010 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.