Laserfiche WebLink
• SAN JOAQUIN COUNTY � • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogoy.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated O ep_rotor: o) Exp.Oate: Inspection <br /> I11� (Z 7 . <br /> t 0 I <br /> Facility address: <br /> 5� ! 1 Z 1"� Product �' 8 ' "{ <br /> Facility contact 10%.6%W I I Title: Phone: <br /> pion ih panel: Piping system: Overfill prevention: <br /> pressurized El Suction ❑Gravity Mechanical ❑Audible/visual <br /> Inspection type: Vio tions: <br /> Routine .2'(Vlonitoring Certification El Installation El Other: M1-RDetect ❑M2-RPrev ❑M-3 Both <br /> �site Technician's Name: ICC Service Technician Exp.Date: Manufacturer's Training: <br /> -�>✓ n5 S F-sb-Vf <br /> # Code Section VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> V=Violation;RV=Re eat Violation V <br /> 1 HSC 25284 No permit to operate <br /> 2 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification not <br /> provided to the EHD at least 48 hours prior to conducting the test <br /> 3 CCR 2711(b)&(c) Current Unified Program Consolidated Forms not on file with the EH13 TFadility and tank form) <br /> 4 HSC 25292.2 • Current financial responsibility documents not on file with the EHD 04MID <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plan)is not current or approved by the local agency <br /> 6 CCR 2712(i) Monitoring and/or response plan is not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years, (M1) <br /> written performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 7 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling;(2) <br /> monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4)results of <br /> sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring equipment, <br /> round water elevations,or other test results;(6)results of inventory readings and reconciliations. <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January 1, 1984)not performed <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST/piping (M1) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br /> 12 HSC 25291(b) UST system monitoring equipment is not operational (M1) <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDC that to activates an (M1) <br /> audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631(a) Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> 17 HSC 25291(f) Line leak detector(s)not installed (M1) <br /> 18 CCR 2635(b)(1) Spill container not installed,failed to contain a minimum capacity of five gallons,or failed to provide (M2) <br /> a means to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br /> 20 CCR 2636(a) Failed to have secondary containment or continuous monitoring(includes conventional suction piping) <br /> 21 HSC 25291(e) Water in 21 containment not removed,analyzed&properly disposed of <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 22 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> roduct was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(2-4)spill containers,UDCs,and <br /> 23c CCR 2715(c),(d),(e) sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted;(c)(6)employee training not <br /> verified;(d)(e)monthly inspection reports not maintained on site for at least 12 months <br /> 23d CCR 2715(f) Designated operator employee training:(1)not performed;(2)not current for at least one employee on site;(3) <br /> Ion not kept <br /> EH I SPECTOR: RECEIVED BY: TITLE: <br /> le <br /> EHD 23-02-002 REV 12/09 Pagel UST INSPECTION REPORT <br />