Laserfiche WebLink
r7 <br />SA14 <br />JOA QUIR COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br />UNDERGROUND STORAGE TANK <br />RESPONSE PLAN - PAGE 2 <br />VI REPORTING AM RECORD KEEPING <br />We will reportftecoid my overfill, spill, or unauthorized release fiwn a UST system as indicated in this plan. <br />Recardalik Relestses: Any unauthorized reftes: from primary containment which am UST operator is " to clean up within eight M bows after the release was <br />detected or should reasonably have been detected, and which does not escape fixan secondary containment, does not increase the hazard of fine or explosion, and does <br />not cause any deterioration of secondary containment, must be recorded in the ficiffity's monitoring records. Monitoring records now include- <br />> The UST operators name and telephone number, <br />> A list of the "m quantities, and concentrations of hazardous substances released; <br />> A description of the actions talm to control and clean up the release; <br />> The method and location ofdisposal of the released hazardous substances, and whether a hazardous waste manifest was or will be used; <br />> A description of actions talien to repair the UST and to prevent future rdeases; <br />> A description of the method used to ractivato interstitial monitoring after replacement or repair of primary cortaintrient. <br />Rqwtable lRelesses: Any overfill, spill, or unauthorized release which escapes ftm secondary containment (or primary containment if no secondary contdnmcftt <br />exists), increases the hazard of fine or explosion, or causes my deterioration of secondary containment, is a reportable release Reportable Teleasm we also recordal& <br />Within 24 hours alker a reptirtable release has been datected, or should have how detected, wo will notify ft local agency administerino the UST program of the <br />mkasr, investigift the release, and tak munediaft measura to stop the relesso. If necessary, or if required by die local agency, remaining stored producVwaste will <br />be removed fim die UST to finthorreleases or flicilitatc corrective action. If= enwgm7 oxists, wii will notify the Soft Office: ofErnergency, Services. <br />Within five (5) warlang days of a reportable release, we will submit to the local agency a &H written report containing all of the following inAirmation to the extent <br />that the' is lmown at do time of filing the report <br />> The UST ownces or opermor's none and telephone murbar, <br />> A Ku of the types, quantities, and concentrations ofluarailous materials released; <br />> The approximate date of the release. <br />> The date an which die release was discovered; <br />> The daft an which the micase was stopped; <br />> A description ofactions taloen to control andikir stop the rdcasc; <br />> A description of corrective and remedial actions, including investigations which wm undertaben and will be conducted to determine the nature and extent of <br />scil, ground water or surface water contamination due to the relcasin <br />> The nwdm*s) oftlearrup imphimented to dati:6 proposod clesnup, actions, and a schedule for implementing the proposed actions; <br />> The method(s) and locadon(s) ofdisposal ofnicand hazardous malmals and any contaminated soils, smundwaW. or suface water. <br />> Copies of any hazardous waste manifests used for off -into transport ofluizardous wastes mociated with clan -up activity; <br />> A description ofpmposed methods; for any tepair orrep lacement of US system prinoury/socondary containment Systems; <br />> A description ofadditional actions taken to prevent Moe relmm <br />We will Mw the reporting procedures described above if any of the following conditions occur: <br />• A recordable unauthorized release can not bee up or is still under investigation within eight (9) hours ofdcft&m*. <br />• Released hazardous substances are discovered at the UST site or in the surrounding arva; <br />• Unusual operating conditions am observed, including erratic behavior ofproduct dispensing equipment sudden low of product or dw unexplained in Of <br />water, in the tank, unleas system equipment is found to be defective and is hnmedW* repaired or replaced, and no teak has occurred; <br />• Monitoring results furan UST system monitoring etpupmentimethods indicate that a release may have: occurrW, unless the irsimWims cQuipment is Awnd to be <br />defective and is manediately repaired, recalitnated, or replaced, and additional monitoring does not confirm the initial results <br />PtecordRetandint- Mondoring records and writboarepot ofunauthorized releases must be maintained on-site (or off -ate at a readily available location, ifapproved <br />by the local agency) for at few 3 yem Hazardous waste d4vkqfflbposd records (e4, manihft) must be maintained for at lead 3 years from the date ofshipmeaL <br />VU OVMEROPE RATOR SIGNATUM <br />CERTIMPICATIOM I cwft that dIs true and accurate to the best of my knowledge. <br />OWNERJOPERATOR S <br />DATE 1170, <br />:2!Z. <br />Octaber7,2008 <br />OWNERIOPERATOR NAME (print) R71. <br />ot/oPERAToR -r= M <br />wrap <br />Milm Kawl0t, for QU& Stop Mukuts, Inc. <br />DftccW of EwhonmMW AM= <br />7— <br />has been reviewed a: MAPPloved [3 Approved With Conditions 0 Disapprwied <br />(Agency Use On&) This plan and: <br />- <br />Local Agency Signature: A1 Datc: <br />UST Respoaft Plan Pa908) - 30 <br />