Laserfiche WebLink
SYWEM SET-UP REPOR <br />OUTPUT RELAY SETUP EVR,ISD SETUP <br />R 1:87 STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK 4: 1 <br />I N -TANK ALARMS <br />T 1:HIGH WATER ALARM <br />T 1:LOW PRODUCT ALARM <br />T 1:SUDDEN LOSS ALARM <br />T 1:GROSS TEST FAIL <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />ISD SITE ALARMS <br />ISE) GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:91 STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK. 0: 2 <br />IN -TANK ALARMS <br />T 2:HIGH WATER ALARM <br />T 2:LOW PRODUCT ALARM <br />T 2:SUDDEN LOSS ALARM <br />T 2:GROSS TEST FAIL <br />LIQUID SENSOR ALMS <br />L 4:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />L 4:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 4:DIESEL 2 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK 0: 3 <br />IN -TANK ALARMS <br />T 3:HIGH WATER ALARM <br />T 3:LOW PRODUCT ALARM <br />T 3:SUDDEN LOSS ALARM <br />T 3:GROSS TEST FAIL <br />LIQUID SENSOR ALMS <br />L 6:FUEL ALARM <br />L 6:SENSOR OUT ALARM <br />L 6:SHORT ALARM <br />2011 Walton Engineering, Inc. <br />EVR TYPE: VACUUM ASSIST <br />VACUUM ASSIST TYPE <br />HEALY VAC <br />NOZZLE A; L RANGE <br />MAX: 1.15 MIN: 0.95 <br />VAPOR PROCESSOR TYPE <br />NONE <br />ANALYSIS TIMES <br />TIME: 10:00 AM <br />DELAY MINUTES: 1 <br />ACCEPT HIGH ORVR: <br />DISABLED <br />ISD HOSE TABLE <br />ID FP FL <br />---------------- <br />HL <br />AA <br />RR <br />01 01 01 <br />02 <br />-------- <br />01 <br />00 <br />02 02 02 <br />02 <br />01 <br />00 <br />03 03 03 <br />02 <br />02 <br />00 <br />04 04 04 <br />02 <br />02 <br />00 <br />05 05 05 <br />02 <br />03 <br />00 <br />06 06 06 <br />02 <br />03 <br />00 <br />ISD AIRFLOW METER MAP <br />ID SERIAL NUM LABEL <br />------------------------ <br />1 52687 DISP 1-2 F <br />2 17064 DISP 3-4 F <br />3 13149 DISP 5-6 F <br />ISD FUEL GRADE HOSE MAP <br />1 2 3 4 <br />FP MHH MHH MHH MHH AA <br />------------------------ <br />01 401 901 301 5 U 1 <br />02 302 402 902 5 U 1 <br />03 303 403 903 5 U 2 <br />04 304 404 904 5 U <br />05 305 405 905 5 U 3 <br />06 406 906 306 5 U 3 <br />LABEL TABLE <br />1: UNASSIGNED <br />2: BLEND'S <br />3: REGULAR <br />4: MID GRADE <br />5: PREMIUM <br />6: GOLD <br />7: BRONZE <br />8: SILVER <br />9: BLEND2 <br />10: BLEND4 <br />3) <br />PMC SETUP <br />FMC VERSION: 01.03 <br />VAPOR PROCESSOR T`lFE <br />NONE <br />PROCESSOR CONTROL LEVEL: <br />NONE <br />SOFTWARE REVISION LEVEL <br />VERSION 330.01 <br />SOFTWARE# 346330-100-B <br />CREATED - 10.07.23.17,25 <br />S -MODULE# 330160 -O04 -a <br />SYSTEM FEATURES: <br />PERIODIC IN -TANK. TESTS <br />ANNUAL IN -TANK. TESTS <br />ISD <br />