My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1580
>
2300 - Underground Storage Tank Program
>
PR0231476
>
COMPLIANCE INFO_2011-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 1:14:37 PM
Creation date
6/23/2020 6:49:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2012
RECORD_ID
PR0231476
PE
2361
FACILITY_ID
FA0000684
FACILITY_NAME
QUIK STOP MARKET #3125
STREET_NUMBER
1580
Direction
W
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
259-090-21
CURRENT_STATUS
01
SITE_LOCATION
1580 W MAIN ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231476_1580 W MAIN_2011-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED F <br />UNDERGROUND STORAGE TANK <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (One form per UST) <br />TYPE OF ACTION (Check one item only. For an UST permanent closure or removal, complete only this section and Sections I, II, III, IV, and IX below) <br />430 <br />X 1. NEW PERMIT ❑ 3. RENEWAL PERMIT ❑ 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: <br />430b <br />„' <br />�K IIII , . 'fid, 'Pf "� :811 <br />1,�"d:�lr 11,i�S% 9;1. «'' �' <br />�V�•1 0." Y"91H . , h f P » f. : '. enc , :.: . �.', : ,,, <br />FACILITY ID # (Agency Use Only)'" la[u91u1 IIII. <br />�`'" Ili' <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) <br />3 <br />Quik Stop #125 <br />BUSINESS SITE ADDRESS 103 CITY <br />104 <br />1580 W. Main Street Ripon <br />I 111 „`�� f', PI 1�1�"'III„'`�''11�°141 ' 1111111 191 III II „ u11� 11II III I I Iu�111 �` � <br />� � �' 111 1 II I ld;r�"I hl <br />f <br />' ;YO �. 1 'A I.6i„ .IID.. v. <br />TANK ID # 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS <br />434 <br />3 Xerxes X 1. A STAND-ALONE TANK <br />[12. ONE IN A COMPARTMENTED UNIT. <br />Complete one page for each compartment in the unit. <br />DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT <br />437 <br />8,000 1 1 <br />111 Fl $ e,'. J11 I. x+.n�4Yliid '45tl: �"" VI, uN <br />�f"n 6,.k 0-P0111, <br />+W {i tlll�¢�IPh'F' <br />yCl" r kl �";. �S.0 <br />p�. ¢,I, }II. .e.i,, <br />TANK USE x la. MOTOR VEHICLE FUELING ❑ lb. MARINA FUELING ❑ lc. AVIATION FUELING <br />439 <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL [HSC §25281.5(c)] <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): <br />439a <br />CONTENTS PETROLEUM: ❑ Ia. REGULAR UNLEADED lc. MIDGRADE UNLEADED ❑ Ib. PREMIUM UNLEADED <br />440 <br />X 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): <br />440a <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ 11. OTHER NON -PETROLEUMS 9ecify4440b <br />1 s <br />1=1111011111 I 111-11i= <br />TYPE OF TANK ❑ 1. SINGLE WALL x 2. DOUBLE WALL ❑ 95. UNKNOWN <br />443 <br />PRIMARY CONTAINMENT ❑ 1. STEEL X 3. FIBERGLASS ❑ 6. INTERNAL BLADDER <br />4aa <br />❑ 7. STEEL+ INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): <br />444a <br />SECONDARY CONTAINMENT ❑ 1. STEEL X 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ❑ 7. JACKETED <br />445 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER(Specify): <br />445a <br />OVERFILL PREVENTION ❑ 1. AUDIBLE & VISUAL ALARMS ❑ 2. BALL FLOAT x 3. FILL TUBE SHUT-OFF VALVE <br />452. <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />�' II141G�, � j1 jj1 �1 <br />PIPING CONSTRUCTION ❑ 1. SINGLE -WALLED x 2. DOUBLE -WALLED ❑ 99. OTHER <br />460 <br />SYSTEM TYPE x 1. PRESSURE ❑ 2. GRAVITY ❑ 3. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION [23 CCR §2636(a)(3)] <br />458 <br />PRIMARY CONTAINMENT ❑ 1. STEEL X 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC <br />464 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99.OTHER(Specify): <br />464a <br />SECONDARY CONTAINMENT ❑ 1. STEEL x 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC <br />4646 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): <br />464c <br />PIPING/TURBINE CONTAINMENT SUMP TYPE ❑ 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE <br />464d <br />VENT PRIMARY CONTAINMENT ❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464e <br />464el <br />VENT SECONDARY CONTAINMENT ❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464f <br />464f1 <br />VR PRIMARY CONTAINMENT ❑ 1. STEEL X 4. FIBERGLASS 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464g <br />464SI <br />VR SECONDARY CONTAINMENT ❑ 1. STEEL X 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464h <br />464h1 <br />VENT PIPING TRANSITION SUMP TYPE ❑ 1. SINGLE WALL x 2. DOUBLE WALL ❑ 90. NONE <br />4641. <br />RISER PRIMARY CONTAINMENT x I. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464j <br />4641 <br />RISER SECONDARY CONTAINMENT ❑ I. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) <br />464k <br />464k1 <br />FILL COMPONENTS INSTALLED x 1. SPILL BUCKET x 3. STRIKER PLATEIBOTTOM PROTECTOR x 4. CONTAINMENT SUMP <br />45la-c <br />.p <br />r 1 1 0 , a 4f y1I IPI i� I t <br />'r mu ��� <br />at <br />,1 <br />CONSTRUCTION TYPE X 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3. NO DISPENSERS ❑ 90. NONE <br />469a <br />CONSTRUCTION MATERIAL ❑ 1. STEEL x 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 99. OTHERS 9eci <br />469b -c <br />Np 11 i G <br />u IIII 1 � II IIII I <br />11 IIII 11 III IV 4 u f 1 <br />MEN" <br />II„�I II .,. a, <br />1111111 1 � � VG +{IIII I II 11I II I :.,h�T1111 1 d' ,N," MA« >. 3 <br />nom: .., w <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ❑ 6. ISOLATION <br />448. <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br />accurate, <br />and in.full compliance with legal requirements. <br />APPLICANT SIGNATURE <br />DATE <br />470. <br />APPLICANT NAME (print) Dulcinea Covan 471. <br />APPLICANT TITLE Compliance Manager <br />472. <br />UPCF UST -B -1/1 Rev. (12/2007) <br />
The URL can be used to link to this page
Your browser does not support the video tag.