Laserfiche WebLink
46 6 <br />San Joaquin u <br />C Environmental I DIRECTOR <br />® Donna Heran, REHS <br />600 East Main Street <br />Stockton, California 95202-3029 PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />�;�P Website: w .sjgov.Org/ehd Kasey Foley, REHS <br />o'R <br />f F <br />Phone: (209) 468-3420 Linda Turkatte, REHS <br />January 12, 2011 Fax: (209) 464-0138 <br />Elite IV <br />2535 Wigwam Drive <br />Stockton, CA 95204 <br />Attn: Denise Guzman <br />Re: Quikstop # 125 SR0061743 <br />1580 Main Street, Ripon CA 95366 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of <br />the application for a permit to replace an ECPU board and perform a coldstart on the <br />underground storage tank (UST) system at the above noted address. The permit has been <br />approved with the following conditions: <br />1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br />District for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval <br />prior to commencing work. All new addenda supersede the previous ones. <br />3. Contact Muniappa Naidu at (209) 468-3439 to arrange the following inspection <br />appointments (a 48-hour notice is required for inspection appointments). Please be <br />aware that inspections for emergency work must be scheduled within five days of permit <br />approval. <br />a. Sensor functionality: Functionality of the monitoring system must be verified to <br />ensure that monitoring has been restored to meet the requirements of Title 23 <br />California Code of Regulations and the Health & Safety Code. Functionality of the <br />monitoring system already verified (1/7/11). <br />4. Qualified service technicians must possess or work under the direct and personal <br />supervision of an individual physically present at the work site who possesses all of the <br />following: <br />a. One of several permissible valid, current contractor's licenses issued by the <br />Contractors State License Board (may be issued to the installation company), or a <br />Tank Tester's license issued to the individual by the State Water Board, and <br />b. A valid, current California UST Service Technician certificate issued by the <br />International Code Council (ICC), and <br />c. A valid, current certificate of training from the manufacturers) of the components) <br />being tested, repaired, or serviced. <br />