Laserfiche WebLink
1�i LQ <br /> + +;i?WHUN BREAK:OFF - <br /> DELIVERY DELAY 5 MIN <br /> PUMP THRESHOLD 10-00% DELI VERV-1i'ELAY , <br /> PUMP THRESHOLD 10.00°;".< R 1 :87 STP ~ <br /> . <br /> TYPE: " <br /> STANDARD <br /> -,NORMALLY CLOSED <br /> TANK#: 1 <br /> IN-TANK ALARMS <br /> T I :HIGH WATER ALARM <br /> T I :LOW PRODUCT ALARM <br /> T 3:Die5el T I :SUDDEN LOSS ALARM, <br /> PRODUCT CODE C T 1 :GROSS TEST 'FAI:L <br /> THERMAL COEFF : .004500 LEAK TEST METHOD <br /> TANK DIAMETER 42.00 - - - - - - - LIQUID SENSOR AIMS <br /> TANK PROFILE S TEST ON DATE ALL TANK .• <br /> FULL VOL 8000 JAN 1 . 1996 L :-•FUEL ALARM <br /> L 2:SENSOR .OUT ALARM <br /> 69.0 INCH VOL : 6563 START TIME 7:52 AM L 2:SHORT ALARM <br /> 46.0 INCH VOL 4057 TEST RATE :0.20 GAL/HR <br /> 25.0 INC.H_VOL : 1531 'DURATION 2 HOURS ISD SITE ALARMS <br /> TST EARLY STOF':DISABLED ISD GROSS PRES. FAIL <br /> i <br /> ISD DEGRD PRES FAIL <br /> FLOAT SIZE: 4.0 IN. ISD VAPOR LEAK FAIL <br /> LEAK TEST REPORT FORMAT <br /> WATER WARNING^ 1 .0 NORMAL ISD HOSE ALARMS <br /> HIGH WATER LIMIT: 2.0 ALL:GROSS COLLECT-FAIL <br /> ALL:DEGRD COLLECT- FAIL <br /> MAS; OR LABEL VOL: 8000 ALL:FLOW COLLECT FAIL <br /> OVERFILL LIMIT 90 <br /> 7200 R 2:91 STP <br /> HIGH PRODUCT 95% TYPE: <br /> 7600 STANDARD <br /> DELIVERY LIMIT 10% NORMALLY CLOSED <br /> 800 <br /> LOW PRODUCT 400 TANK #: 2 <br /> LEAK ALARM LIMIT: 99 LIQUID SENSOR SETUP <br /> SUDDEN LOSS LIMIT: 99 - - - - - - - - - - - - IN-TANK ALARMS <br /> TANK TILT 3.00 - T 2:HIGH WATER ALARM <br /> PROBE OFFSET 0.00 L 1 :87 TRI-STATE ANNULAR <br /> FLOAT} T 2.LOW PRODUCT ALARM <br /> CATEGORY ANNULAR SPACE T 2:0 ROSS TEST FAILT 2:SUDDEN LOSS ALARM <br /> -SIFHON MANIFOLUED TANKS <br /> T#: NONE LIQUID SENSOR ALMS <br /> LINE MANIFOLDED TANKS L 4:FUEL HIAR(°1 <br /> T#: NONE L 2:87 STP SUMP L 4:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 4:SHORT ALARi°i;.. <br /> CATEGORY : STP SUMP <br /> LEAK MIN PERIODIC: 0% I,SD SITEALARMS <br /> 0 ISD GROSS PRES FAIL <br /> L 3:91 ANNULAR ISD DEGRD PRES FAIL <br /> LEAK MIN ANNUAL 070 TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> 0 CATEGORY ANNULAR SPACE <br /> ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL <br /> PERIODIC TEST TYPE ALL:DEGRD COLLECT FAIL <br /> STANDARD L 4:91 _STP SUMP ALL:FLOW COLLECT FAIL, <br /> TRI-STATE (SINGLE FLOAT) <br /> ANNUAL TEST FAIL CATEGORY : STP SUMP R 4:DIESEL 2 <br /> ALARM DISABLED TYPE' <br /> ST <br /> PERIODIC TEST FAIL `, ( L 5:DIESEL ANNULAR NORt _ <br /> ALARM DISABLED TRI-STATE (SINGLE FLOAT) y <br /> j <br /> CATEGORY ,: ANNULAR SPACE <br /> CROSS TEST FAIL <br /> ALARM DISABLED'' <br /> A( OFF L 6:D I ESEL STP ' <br /> P? OFF TR I-" ""T tqr.LE FLOAT) <br /> i CATE <br />