My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1580
>
2300 - Underground Storage Tank Program
>
PR0231476
>
COMPLIANCE INFO_2017-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 11:27:01 AM
Creation date
6/23/2020 6:49:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017-2018
RECORD_ID
PR0231476
PE
2361
FACILITY_ID
FA0000684
FACILITY_NAME
QUIK STOP MARKET #3125
STREET_NUMBER
1580
Direction
W
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
259-090-21
CURRENT_STATUS
01
SITE_LOCATION
1580 W MAIN ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231476_1580 W MAIN_2017-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION/ TEST DATE: June 06, 2018 <br />A1. FACILITY <br />INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />A2. OWNER <br />Name <br />Quik Stop Market #125 <br />Name <br />Quik Stop Markets, Inc. <br />Address <br />1580 W. Main Street, Ripon, CA 95366 <br />❑ <br />Address <br />4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />Model: <br />Phone # <br />510-657-8500 <br />Contact <br />Roger Batra <br />Annular Space or Vault Sensor <br />Contact <br />Debbie Markovich <br />A3. C U P A <br />Model: 0794380-208 <br />Model: <br />❑ <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Mechanical Line Leak Detector <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />❑ <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />May 23, 2018 <br />Model: <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Zuna Barker <br />Tank Overfill / High -Level Sensor <br />Contact <br />Veronica Freitas <br />Phone # <br />209-468-3442 <br />❑ <br />Phone # <br />916-373-1166 <br />B. <br />INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />B1: TANKS <br />Tank #1 (Product): 87 <br />Tank #2 (Product): 91 <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />• <br />Annular Space or Vault Sensor <br />Model: 0794390-409 <br />Annular Space or Vault Sensor <br />Model: 0794390.409 <br />• <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Fill Sump Sensor(s) <br />Model: 0794380-208 <br />Model: <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Fill Sump Sensor(s) <br />Model: 0794380-208 <br />Model: <br />0 <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />0 <br />Mechanical Line Leak Detector <br />Model: Red Jacket FX <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />Tank #3 (Product): Diesel <br />Tank #4 (Product): _ <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />0 <br />Annular Space or Vault Sensor <br />Model: 0794390-409 <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />0 <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />I� <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />B2: DISPENSERS/UDC's <br />Dispenser # : 1-2 <br />Dispenser # : 3-4 <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />Shear Valves <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # : 5-6 <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />Shear Valves <br />❑ <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # : <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Dispenser Containment Sensor(s) <br />Model: <br />❑ <br />Shear Valves <br />❑ <br />Shear Valves <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing th <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply <br />■ System set-up ■ Alarm History Report <br />JJ0 WALTON <br />Signature: - ; -, rk'�t � � ENGINEERING, INC. <br />Technician / Cert #: Anthony Reyes B46116 8293772 Date: June 6, 2018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.