MONITORING SYSTEM CERTIFICAT10N <br />JET®2017 <br />CERTIFICATION /TEST DATE: June 9, 2017 <br />Al. FACILITY <br />■ Yes <br />❑ No * <br />A2. OWNER <br />■ Yes <br />Name <br />Quik Stop Market #125 <br />■ Yes <br />Name <br />Quik Stop Markets, Inc -r- r%01, T MENIT <br />Address <br />1580 W. Main Street, Ripon, CA 95366 <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />Address <br />4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />❑ No* <br />❑ N/A <br />❑ No* <br />Phone # <br />510-657-8500 <br />Contact <br />Roger Batra <br />❑ Yes * <br />contact <br />Debbie Markovich <br />.'r <br />D. RESULTS OF TESTING / SERVICING <br />Make / Model of Monitoring System: Veeder-Root TLS -350 SN# <br />Software Version Installed: <br />Complete the following checklist: <br />" In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Removed water from all fill sumps. <br />©2017 Walton Engineering, Inc. <br />Page 2 of 3 <br />■ Yes <br />❑ No * <br />Is the audible alarm operational? <br />■ Yes <br />❑ No * <br />Is the visual alarm operational? <br />■ Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />■ Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />❑ Yes <br />❑ No* <br />■ N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modems) <br />operational? <br />■ Yes <br />■ Yes <br />❑ No* <br />❑ N/A <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) ■ Sum p/Trench sensors; [3 Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks an sensor failure/disconnection? <br />■ Yes <br />❑ No* <br />❑ N/A <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% <br />❑ Yes * <br />■ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />■ Yes * <br />❑ No <br />Was any liquid found inside any secondary containment systems designed as dry systems? <br />(Check all that apply) [I Product; ■Water. If yes, describe causes in Section E, below. <br />■ Yes <br />❑ No * <br />Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable. <br />■ Yes <br />L <br />❑ No* <br />" In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Removed water from all fill sumps. <br />©2017 Walton Engineering, Inc. <br />Page 2 of 3 <br />Is all monitoring equipment operational per manufacturer's specifications? <br />" In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Removed water from all fill sumps. <br />©2017 Walton Engineering, Inc. <br />Page 2 of 3 <br />