Laserfiche WebLink
SYSTEM SET-UP <br />E LOAT) <br />REPORT 2) <br />(Page <br />_._ LIGUID SENSOR SETUP <br />- - - - - - - - - - - - <br />IN -TANK ALARMS <br />T 2:HIGH WATER ALARM <br />L 1:87 ANNULAR <br />T 2 -LOW PRODUCT ALi'lRti <br />TRI-STATE (SINGLE FLOAT) <br />T 2.SUDDEN LOSS ALARM <br />CATEGORY : ANNULAR SPACE <br />T 2:GROSS TEST FAIL <br />APR 16 2016 <br />LIQUID SENSOR ALMS <br />L 4: FUEL ALARM <br />L 2:87 STP SUMP <br />L 4:SENSOR OUT ALARM <br />' <br />L 4:SHORT ALARM <br />T :Diasi TRI-. TATE (SINtL F <br />, <br />PRODUCT CODE C CATEGORY STP SUMP ISD SITE ALARMS <br />THERMAL COEFF :.004500 ISD GROSS PRES FAIL <br />TANK DIAMETER 92.00 L 3'.91 ANNULAR ISD DEGRD PRES FAIL EVR,'ISD SETUP <br />TANK PROFILE 4 PTS TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br />FULL VOL 8000 CATEGORY : ANNULAR SPACE <br />69.0 INCH VOL 6563 ISD HOSE ALARMS <br />46,0 INCH VOL 4057 ALL:GROSS COLLECT FAIL EVR TYPE: VACUUM ASSIST <br />23.0 INCH VOL 1531 ALL:DEGRD COLLECT FAIL VACUUM ASSIST TYPE <br />L 4:91 STP SUMP ALL:FLOW COLLECT FAII. HEALY VAC <br />FLOAT SIZE: 4.0 IN. <br />TRI-STATE tSINiaGE FLOAT) R 4:DIESEL 2 NOZZLE A/L RANGE <br />CATEGORY STP SUMP TYPE: MAX: 1.15 MIN: 0.95 <br />WATER WARNING 1.0 STANDARD <br />HIGH WATER LIMIT: 2.0 L 5:DIESEL ANNULAR NORMALLY CLOSED VAPOR PPOCESSOR TYPE <br />MAX OR LABEL VOL: 5000 TRI-STATE (SINGLE FLOAT? NONE <br />TANK #: 3 <br />OVERFILL LIMIT 90% <br />CATEGORY ANNULAR SPACE <br />7200 ANALYSIS TIMES <br />HIGH PRODUCT 95% IN -TANK ALARMS TIME: 10:00 AM <br />7000 L 6:DIESEII STP T 3:HIGH WATER ALARM DELAY MINUTES: i <br />DELIVERY LI(IIT 10'7 TRI-STATE (SINGLE FLOAT) T 3:LOW PRODUCT ALARM <br />000 CATEGORY : STP SUMP T 3.SUDDEN LOSS ALARM <br />T 3:GR02S TEST FAIL ACCEPT HIGH ORVR: <br />LOW PRODUCT 400 DISABLED <br />LEAK ALARM LIMIT: 99 LIQUID SENSOR AIMS <br />SUDDEN LOSS LIMIT 99 L E:FUELALARM ISD HOSE TABLE <br />TANK TILT 3,00 L 6:SENSOR OUT ALARM ID FP FL HL AA RR <br />PROBE OFFSET 0.00 L 6:SHORT ALARM _.__..__._.-------- ---_-____._. <br />01 01 01 02 01 02 <br />02 02 02 02 Oi 02 <br />SIPHON MANIFOLDED TANKS 03 03 03 02 02 02 <br />T#: NONE 04 04 04 02 02 02 <br />LINE MANIFOLDED TANKS 05 05 05 02 03 02 <br />T#: NONE 06 06 06 02 03 02 <br />OUTPUT RELAY SETUP <br />LEAK MIN PERIODIC: 0% - - - - - - - - - _ _ ISD AIRFLOW METER MAP <br />0R 1:57 STP ID SERIAL NUM LABEL <br />LEAK MIN ANNUAL 01% PE' SMARTSENSOR SETUP 1-52687-- _-DISP 1-2 F <br />STANDARD <br />0 NORMALLY CLOSED 2 17064 DIEP 3-4F <br />- - - _ _ _ •. - - 3 54237 DISP 5-6 F <br />TANK r#„ I = I:DISP 5-6 FLOW <br />PERIODIC TEST TYPE CATEGORY AIR FLOW METER <br />STANDARD ISD FUEL GRADE HOSE MAP <br />IN -TANK ALARMS s 2: D I SP 1-2 FLOW 1 2 3 4 <br />A14NUAL TEST FAIL T I:HIGH WATER ALARM CATEGORY AIR FLOW METER FP MHH MHN MHH MHH AA <br />ALARM DISABLED T 1:LOW PRODUCT ALARM ­_---------- .-__-___-__._. <br />T i:SUDDEN LOSS ALARM s 3:DISP 3-4 FLOW 01 401 901 301 5 U i <br />PERIODIC TEST FAIL T I:GROSS TEST FAIL CATEGORY AIR FLOW METER 02 302 402 902 5 U 1 <br />ALARM DISABLED 03 303 403 903 5 U 2 <br />LIQUID SENSOR ALMS 5 4;PRESSURE 04 304 404 904 5 U 2 <br />GROSS TEST FAILCATEGORY VAPOR PRESSURE 05 305 405 905 5 U 3 <br />ALARM DISABLED L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM 06 406 906 306 5 U 3 <br />ANN TEST AVERAGING: OFF L 2:SHORT ALARM <br />PER TEST AVERAGING: OFF ISD SITE ALARMS LABEL TABLE <br />TANK TEST' NOTIFY: OFF ISD GROSS FRES FAIL 1: UNASSIGNED-_____.__.- <br />ISD DEGRD FRES FAIL <br />ISD VAPOR LEAK FAIL 2: BLENDS <br />TNK TST SIPHON BREAKOFF 3: REGULAR <br />ISD HOSE ALARMS 4: MID GRADE <br />DELIVERY DELAY 5 MIN ALL:GROSS COLLECT FAIL 5 PREMIUM <br />PUMP THRESHOLD 10.100% ALL:DEGRD COLLECT FAIL 6: GOLD <br />ALL:FLOW COLLECT FAIL 7: BRONZE <br />8: SILVER <br />R 2:91 STP 9: HLEND2 <br />TYPE: 10: BLEND4 <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 2 <br />02016 Walton Engineering, Inc. <br />