Laserfiche WebLink
Ll <br />r� <br />SWRCB, January 2006 <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (f applicable) should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: BW #98 - H & M MARKET I Date of Testing: JUL 20, 2009 <br />Facility Address: 2501 E. JACKSON AVENUE, ESCALON, CA 95320 <br />Facility Contact: ROHDA HENRY <br />I Phone: (209) 549-5612 <br />Date Local Agency Was Notified of Testing: JUL 13, 2009 <br />Name of Local Agency Inspector (ifpresent during testing): MUNIAPPA NAIDU <br />Company Name: TANK-TEK ENVIRONMENTAL CORPORATION <br />Technician Conducting Test: MIKE LAWRENCE <br />Credentials': ® CSLB Contractor ® ICC Service Tech. ® SWRCB Tank Tester ❑ Other (Specie) <br />License Number(s): 803705 (CSLB Contractor) -- 1048103 -UT (ICC Service Tech.) -- 90-1200 (SWRCB Tank Tester) <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other (Spec) <br />Test Equipment Used: VISUAL <br />Equipment Resolution: <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />87 FILL <br />91 FILL <br />DIESEL FILL <br />Bucket Installation Type: <br />® Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in Sump <br />❑ Direct Bury <br />❑ Contained in Sump <br />Bucket Diameter: <br />11.50" <br />11.50" <br />11.50" <br />Bucket Depth: <br />15.50" <br />15.00" <br />20.00" <br />Wait time between applying <br />vacuum/water and start of test: <br />0 <br />0 <br />0 <br />Test Start Time (Tj): <br />9:00 AM <br />9:00 AM <br />9:00 AM <br />Initial Reading (Rj): <br />14.00" <br />13.50" <br />18.50" <br />Test End Time (TF): <br />10:00 AM <br />10:00 AM <br />10:00 AM <br />Final Reading (RF): <br />14.00" <br />13.50" <br />18.50" <br />Test Duration (TF — Tj): <br />1 HR <br />1 HR <br />1 HR <br />Change in Reading (RF - Rj): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />® Pass ❑ Fail <br />Z Pass ❑ Fail <br />0 Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: =" ``'`` Date: JUL 20, 2009 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />