My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1532
>
2300 - Underground Storage Tank Program
>
PR0231522
>
COMPLIANCE INFO_1997-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 12:44:18 PM
Creation date
6/23/2020 6:49:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2012
RECORD_ID
PR0231522
PE
2361
FACILITY_ID
FA0004051
FACILITY_NAME
UPS - Stockton
STREET_NUMBER
1532
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1532 N Broadway Ave
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231522_1532 N BROADWAY_1997-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br />4onitoring System Certification <br />D. Results of Testing/Servicing <br />Software Version Installed: 17.02 <br />Complete the foliowin checklist: <br />Yes <br />No* <br />Is the audible alarm operational? <br />Yes <br />No* <br />Is the visual alarm operational? <br />Yes <br />No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Yes <br />No* <br />Were all sensors installed at Iowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />X Yes <br />No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />operational? <br />Yes <br />No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) M Sump/Trench Sensors; [0 Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? -n-g Yes; ❑ No. <br />Yes <br />No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating ro erl If so, at what percent of tank capacity does the alarm trigger? <br />Yes* <br />No No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />Yes* <br />X No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br />Product; Water. If yes, describe causes in Section E, below. <br />Yes <br />❑ No* <br />Was monitoring astern set -u reviewed to ensure pLoper seWq s? Attach set up reports, if applicable <br />Yes I <br />❑ No* <br />Is all monitoring eq!i ment operational per manufacturer's s ecifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.