Laserfiche WebLink
jd0L <br /> --IRTFIED PROGRAM CONSOLIDATED FOW <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN -(Page 2 of 2) <br /> VI. UNDER DISPENSER CONTAINMENT (UDC)MONITORING (Check all <br /> that apply) <br /> UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> ED 1.CONTINUOUS ELECTRONIC MONITORING [1 2.FLOAT AND CHAIN ASSEMBLY ED 3.ELECTRONIC STAND-ALONE 490-54a. <br /> 171 4.NO DISPENSERSEl 99.OTHER(Specify) 490-54b. <br /> ............... ............-..........-.......... ­­.................. ........................... ...................I............................................................................................................- ............................................................................................................................................................................................................................................---- <br /> LEAK MONITOR MANUFACTURER:Veeder Root TLS-350 490-55, MODEL#:0847090-022 490-56. <br /> LEAK SENSOR MANUFACTURER:Veeder Root Stand Alone 490-57. MODEL#(S):001 490-58. <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. [:1 a.YES ED b.No 491-59. <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. [:1 a.YES ED b.No 490-60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. El a.YES [I b.NO 490-61. <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. [D a.YES El b.No 490-62. <br /> ...............I..................__..............................­­­................. ....................­­_.......................--.1-1.........................................................................-......................................... ..............................................­­­­.......................................... ..............................................................................................................................-......................................... <br /> UDC CONSTRUCTION IS: 1.SINGLE WALL ❑ 2.DOUBLE WALL 490-63, <br /> IF DOUBLE WALL: 490-64a. <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ a.LIQUID El b.PRESSURE F1 c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. 0 a.YES [:1 b.NO 490-64b. <br /> VII. PERIODIC SYSTEM TESTING <br /> ❑ I.ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490-65. <br /> LEAK DETECTION(ELD)MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.123 CCR 12644.11 <br /> 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490-66. <br /> 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490-67. <br /> VIII. RECORD KEEPING <br /> The following monitoring/maintenance records are kept for this facility: 490-68. <br /> El a.ALARM LOGS 0 b.VISUAL INSPECTION RECORDS ❑ c.TANK INTEGRITY TESTING RESULTS <br /> El d.SIR TESTING RESULTS(and supporting documentation records) ❑ c.TANK GAUGING RESULTS(and supporting documentation records) <br /> El f.ATG TESTING RESULTS(and supporting documentation records) ❑ g.CORROSION PROTECTION 60-DAY LOGS <br /> El h.EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> IX TRAINING <br /> ED Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties: 490-69a. <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> El THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) 490-69b, <br /> ED OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) 490-69c. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-69e. <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: HANDBOOK FOR TANK OWNERS - MANUAL AND 490-69f. <br /> STATISTICAL INVENTORY RECONCILIATION <br /> ❑ SWRCB PUBLICATION: UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS 490-698. <br /> ❑ OTHER(Specify): 490-69h. <br /> 490-69i. <br /> This facility has a Designated UST Operator who has passed the California UST System Operator Exam administered by the International Code Council 490-70. <br /> (ICC). The Designated UST Operator will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 <br /> days of hire.This training will include,but is not limited to,the following: <br /> > Operation of the UST systems in a manner consistent with the facility s best management practices. <br /> > The facility employee s role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br /> > The facility employee s role with regard to spills and overfills as specified in the facility s UST Response Plan. <br /> > Name(s)of contact person(s)for emergencies and monitoring alarms. <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 490-71. <br /> Note: Designated Operator inspections occurring monthly and include tripping/alarming monitoring system. In order <br /> to preserve alarm history the Designated Operator will print out alarm history/log prior to completing monthly <br /> inspection and will affix to DUSTO. <br /> XI. PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: 1.)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered <br /> by this plan occurs;2.)all conditions that indicate a possible release are investigated;and 3.)all monitoring records are maintained properly. <br /> .............. I............................­.­­ -1 1.11.11 ....................­­­ ....................-.1-111-1--................. I............................... .................................­­___ I ............I ........................................................................................ ....... ......... ............ ... <br /> THE FOLLOWING PERSON(S)ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTENANCE: <br /> NAME: Kasi Montgomery 490-72. TITLE:Plant Engineering Supervisor 490-73. <br /> NAME: Jason Schoon 490-74. TITLE:District Environmental Coordinator 490-75. <br /> The Designated UST Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the informatig"rovided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE DATE: 490-77. <br /> am7r_7_� /2- <br /> REPRESENTING:[]I.Tank Owner/Opuator J72.Fa61itj0ivner/0;erator 0 3.Authorized Repre entafiveofOwner 490-76. <br /> V <br /> UPCF UST-D(12/2007)-3/5 www.unidocs.org <br />