My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1532
>
2300 - Underground Storage Tank Program
>
PR0231522
>
COMPLIANCE INFO_1997-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 12:44:18 PM
Creation date
6/23/2020 6:49:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2012
RECORD_ID
PR0231522
PE
2361
FACILITY_ID
FA0004051
FACILITY_NAME
UPS - Stockton
STREET_NUMBER
1532
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1532 N Broadway Ave
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231522_1532 N BROADWAY_1997-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification 0 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 17.02 <br /> Complete the following checklist: <br /> _ffl_Yes No* Is the audible alarm 2perational? <br /> _@ <br /> Yes No* Is the visual alarm 2perational? <br /> Xes No* Were all sensors visually inspected,fimctional!j tested,and confirmed 22 ? <br /> 0 Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their pro2er ogeration? <br /> M Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> operational? <br /> Yes No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) S Sump/Trench Sensors; 0 Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? a. Yes; ❑No. <br /> Yes U No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill 20int(s)and operating RropElj? If so,at what percent of tank capacity does the alarm tri er? <br /> U Yes* [0 No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all E21acement Rarts in Section E,below. <br /> Yes* 13 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) U <br /> Product; Water. If yes,describe causes in Section E,below. <br /> YesU No* Was Lnonitorin system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> Yes ❑ No* Is all T22itonin eLuipmento perational per manufacturer's Mecifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.