My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1996
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1532
>
2300 - Underground Storage Tank Program
>
PR0231522
>
COMPLIANCE INFO_1986-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 12:00:10 PM
Creation date
6/23/2020 6:49:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1996
RECORD_ID
PR0231522
PE
2361
FACILITY_ID
FA0004051
FACILITY_NAME
UPS - Stockton
STREET_NUMBER
1532
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1532 N Broadway Ave
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231522_1532 N BROADWAY_1986-1996.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
465
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IPWIED PROGRAM CONSOLIDATED FO $\ <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 q) l I°3 <br /> (two pagan �) <br /> Pap_of <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local-only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME SmneasFACIIfIYNAMHorDBA-DoingBa�neasAs) FACILITY ID: i <br /> `L rdiG� �At 3 <br /> LOCATION WITHIN SITE(optional) 431 <br /> L TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landtmarlm shall be submitted to the local geacy.) <br /> TANK ID# 432 TANK MANUFACTVRER 433 COMPARTMENTALIZED TANK ❑Yes WN. 434 <br /> >"lzQ ! �' �Q�t t if••Yes",canplete one page for each compeIIment. <br /> DATE INSTALL (YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 99/ rr, Gnu J <br /> ADDITIONAL DESCRIPTION(Foriowl ae ody) 438 <br /> H.TANK CONTENTS <br /> M11" <br /> �TANK USE 439 PETROLEUM TYPE 440 <br /> L'1 1.MOTOR VEHICLE FUEL le_ REGULAR UNLEADED ❑2 LEADED ❑5. JET FUEL <br /> (ifin dcompiete Petroleum Type) ❑1b. PREMIUM UNLEADED [13- DIESEL ❑6. AVIATION FUEL <br /> [12. NON-FUEL PETROLEUM ❑1 c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazmdons Meteusis Inventory page) 441 CAS#(from Hmrdoos Materiels inventory page) 442 <br /> ❑4.HAZARDOUS WASTE f� �J9 �7�y,s, rye/ <br /> (Includes Used Oil) i,y / �(V�1(� U l�' 2 `V r" 3 ' " <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK 1. SINGLE WALL ❑3. SINGLE WALL WITH 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one dem only) // EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> 13 DOUBLE WALL [14. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL RYFIBERGLASS/PLASTIC 5. CONCRETE 0 95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS [18. FRP COMPTIBLE W/100a/o METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑I. BARE STEEL 3. FIBERGLASS/PLASTIC El 5. CONCRETE 0 95. UNKNOWN 445 <br /> (Check one item only) ❑2 STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL [199.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED ❑3.EPDXY LINING S.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ❑6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑I MANUFACTURED CATHODIC WiFIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION [14 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item arty) ❑2 SACRIFICIAL ANODE (Forlocal-only) <br /> SPILL AND OVERFILL YEAR INSTALLED - 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (ick an that may) ii-I SPILL CONTAINMENT <br /> QT ❑3 FILL TUBE SHUT OFF VALVE <br /> ['2 DROP TUBE CK BALL FLOAT ❑4 EXEMPT <br /> ❑3 STRIKER PLATE <br /> IV.TANK LEAK DETECTION(A desorption of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(check an that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 V ADOSE ZONE ❑2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR)BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MOIDAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(12/99 revised) 10 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.