My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
verizom' <br /> September 6,2017 RECEIVED <br /> Inspector Elena Manzo 5 E P 0 6 2017 <br /> San Joaquin County Environmental Health Department <br /> 1868 East Hazelton Avenue ENVIRONMENTAL HEALTH <br /> Stockton, California 95205-6232 <br /> DEPARTMENT <br /> Re: Return to Compliance Certification for Verizon Business KINGCA(13 850 N <br /> Devries Rd.,Lodi, CA) <br /> Dear Inspector Manzo: <br /> Enclosed and below are the August 30,2017 inspection report for the above- <br /> referenced site, a response to each listed items, corresponding documentation and a <br /> signal return to compliance certification. Each item is discussed below: <br /> Item#103:The site has more than one address associated with it.The address listed <br /> for the site's financial responsibility has been updated in CERS to represent the <br /> address your agency has on file for the site. <br /> Item#105: The fill tube shut-off valve has been identified as the primary overfill in <br /> the UST monitoring plan updated in CERS. <br /> Item#201: Sunwest has indicated that the 2016 monitoring system certification was <br /> performed on 9-1-2016 not 9-2-2016 as the copy onsite shows. Sunwest also has <br /> indicated that on 9-1-2016,the Sunwest technician entered the wrong date on the <br /> monitoring system certification.The corrected report is enclosed.Page 2 of the <br /> designated operator inspection reports also demonstrates compliance with monthly <br /> inspections of the unburied piping <br /> Item#204: This is a suction system and has no leak detector.The updated <br /> monitoring plan in CERS has been revised to remove electronic line leak detector <br /> performs 3 GPH leak test. <br /> Item #209: According to Sunwest, the monitoring system certification was <br /> performed on 9-1-2016, not 9-2-2016. The corrected report is attached and the <br /> monthly inspection reports reflect the 9-1-2016 date. All alarms created during the 9- <br /> Verizon, 18850 Orange Street, Bloomington, CA 92316, Voice 909/879-2712 Fax 909/879-2680 <br />
The URL can be used to link to this page
Your browser does not support the video tag.