My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FU <br /> San Joaquin County <br /> Environmental Health Department S E p f, ?017 <br /> 1868 East Hazelton Avenue,Stockton,Califomia'95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s ov.org/ehd <br /> WE ITW <br /> Facility flame: Facility Address: Date: <br /> VERIZON BUSINESS:KINGCA 13850 N DE VRIES RD,LODI August 30,2017 <br /> Item# Remarks <br /> 201 CCR 2712(b)Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The most recent monitoring <br /> system certification report(dated 9-2-2016)was not onsite.These records shall be maintained on site for at least <br /> three years. Monitoring records Include:(1)date and time of all monitoring or sampling;(2)monitoring equipment <br /> calibration and maintenance records;(3)results of any visual observations;(4)results of sample analysis performed <br /> a lab or In the field;(5)logs of all readings of gauges or other monitoring equipment,ground water elevations,or <br /> other test results;(6)results of inventory readings and reconciliations. Immediately locate and maintain all <br /> maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br /> This is a Class 11 violation. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection,the onsite plan indicated that an <br /> Electronic Line Leak Detector Performs 3 GPH Leak Test is available onsite,no such leak detector was observed at <br /> the time of inspection.A copy of these plans shall be accessible on site at all times. Immediately locate and retain a <br /> copy on site. <br /> This is a Class II violation. <br /> 209 CCR 2715(c)Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates for the monitoring system certification on the <br /> October 2016 through July 2017 designated operator monthly inspection reports. The test date was listed as <br /> 9-1-2016 Instead of 9-2-2016 on all reports.Also,all alarms which occurred on 9-2-2016 were not documented on <br /> the 10-4-2016 designated operator inspection report.During the monthly inspection,the designated operator shall <br /> check that all required testing and maintenance for the UST system have been completed and document the dates <br /> they were done. Ensure that designated operators performing monthly inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a Class 11 violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 9-30-2017. <br /> Please be aware that as of January 1,2014,facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS):UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator:Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> FA0003848 PRO231547 SCO01 08/30/2017 <br /> EHD 23-01 Rev.09=18 Page 4 of 5 Underground Storage Tank Program OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.