EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 0 <br /> SWRCB,January 2002 Page 6 of 7 <br /> 8.FILL RISER CONTAINMENT SUMP <br /> Facility is Not Equipped With Fill Riser Containment Sumps 13 <br /> Fill Riser Containment Sumps are Present,but were Not Tested 13 <br /> Test Method Developed By: ®Sump Manufacturer 0 Industry Standard ®Professional Engineer <br /> ®Ocher(Specifi) <br /> Test Method Uses: ®Pressure 13Vacuum N Hydrostatic <br /> [3 Other(Specify) <br /> Test Equipment Used: INCON TS-STS Equipment Resolution: 0.001" <br /> ESIMMMMMEME= <br /> Fill Sump# I Fill Sump# Fill Same# Fit!Sum p# <br /> Sump Diameter: 46" <br /> Sump Depth: 74" <br /> Height from Tank'rop to Top of 31 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 2911 <br /> Electrical Penetration: <br /> Condition of sump prior to CLEAN llo- V D <br /> testing: <br /> Portion of Sump Tested 35" <br /> Sum e Material: FIBERGLASS 0 L V fJ V <br /> Wait time between applying <br /> presstireYvacuum/water and 30 MIN. TH <br /> starting test: ENVIF ON ENTAL-HO L <br /> Test Start Time: 1:06 pmll:26 j2m L)EPAFffMENT <br /> Initial Reading(R,): 5.1517"/5.1508" <br /> Test End Time: 1:21 pm/1:41 pin <br /> Final Reading(RF): 5.1510"/5.1505" <br /> Test Duration: 2x15 min. <br /> -Change in Readin2(R )1 -0.0003" <br /> Pass/Fail Threshold or Criteria: 0.002" <br /> & <br /> Is there a sensor in the sump? yes <br /> Does the sensor alarm when <br /> either product or water is yes <br /> detected? <br /> Was sensor removed for testing? yes <br /> Was sensor properly replaced and yes <br /> verified functional after testing? <br /> Comments- (include iqlbi-mation on repairs made prior to testing, and recommended follow-up.ft)i-failed tests) <br /> Revision: <br />
The URL can be used to link to this page
Your browser does not support the video tag.