My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web: www.sigov.ora/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 3 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 09/13/10 <br />Facility Address: MCI dba Verizon Business 13850 N. De Vries Rd Lodi, CA 95240 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I CLASS 11, or MINOR -Notice to Com <br />On site to conduct routine inspection and witness the annual monitoring system certification testing. <br />9. A small amount, about half a cup of red dye diesel was at the bottom of the piping/transition sump <br />next to the generator building. The underground storage tank system shall be operated to prevent <br />unauthorized releases. Immediately have a properly licensed, trained, and certified contractor trouble <br />shoot the leak and if needed, replace or repair the failed piping under permit and inspection of the EHD. <br />If the failed component can't be replaced immediately, there is a possibility that the UST system may be <br />red tagged to prevent fuel inputs. Inform this office of what will be done to address this issue. <br />14. A small amount, about half a cup of red dye diesel was at the bottom of the piping/transition sump <br />next to the generator building. All primary containment must be product tight. Immediately have a <br />properly licensed, trained, and certified contractor trouble shoot the leak and if needed, replace or repair <br />the failed piping under permit and inspection of the EHD. If the failed component can't be replaced <br />immediately, there is a possibility that the UST system may be red tagged to prevent fuel inputs. Inform <br />this office of what will be done to address this issue. Repeat Violation. <br />22. A small amount, about half a cup of red dye diesel was at the bottom of the piping/transition was not <br />recorded. Any release from the primary containment that does not escape the secondary containment <br />and was cleaned up within eight hours of being detected shall be recorded with the following information: <br />1. Operator's name and phone number <br />2. List of types, quantities, and concentrations of hazardous substances released <br />3. Description of actions taken to control and clean the release <br />4. Method and location of disposal of the released substances <br />5. Description of actions taken to repair and prevent future releases <br />6. Description of method used to reactivate interstitial monitoring after repair or replacement of <br />primary containment <br />Immediately record this release with the information required, and maintain it on site with the facility's <br />monitoring records. Submit a copy of the recordable release statement to the EHD by 10-13-10. Repeat <br />Violation. Blank copy of the Recording Requirements for Unauthorized Releases form was provided. <br />#23c The designated operator monthly inspection report for August 2010 was not found on site. <br />Designated operator monthly inspection reports for the previous twelve months shall be retained on site. <br />Locate and ensure that copies of the previous twelve months of designated operator monthly inspection <br />reports are maintained on site. Submit a copy of the August 2010 designated operator monthly report to <br />EHD by 10-23-10. Repeat Violation. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($122). <br />THIS FACILITY IS SUWT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD InspectR <br />Title: <br />5&- j�I.EZ-aJ-- iZZ-tfi <br />EHD 23-02-003 Rev 08/10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.