My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 3:48:09 PM
Creation date
6/23/2020 6:49:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IED PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION (one form per UST) <br /> FTY�PEOFACTIION (Check one item only. For a UST closure or removal,complete only this section and Sections I,A III,IV,and IV below) 430. <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a. I DATE EXISTING UST DISCOVERED: 430b. <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) _ - '4 1 <br /> 1. <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3. <br /> MCI, dba, Verizon Business <br /> BUSINESS SITE ADDRESS 103. 1 CITY 104. <br /> 13850 N. DeVries Road Lodi <br /> H. TANK DESCRIPTION <br /> TANK ID# 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> 1 `�R 6l�l�o i Xerxes ® 1.A STAND-ALONE TANK Complete one page for each <br /> ❑ 2.ONE IN A COMPARTMENTED UNIT compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS IN THE UNIT 437. <br /> 1985 550 1 <br /> III. TANK USE AND CONTENTS <br /> TANK USE ❑ la.MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING ❑ lc.AVIATION FUELING 439. <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ® 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439a. <br /> .......................................................................................................---............_....._...._............................._...................................................................................................................................................... <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 440. <br /> ® 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM(Specify): 440a. <br /> .............................................................................................................................- .._...................._............................................................................................................................................................................................._.................. ............................................. <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHERNON-PETROLEUM(Specify): 440b. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443. <br /> ................................................................................................................... <br /> ........................................_........................_.._.................................................__._......................-.......-.................................................................................................................................................................................................-.................................................................................. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444. <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN [_199.OTHER(Specify): 444a. <br /> ................................................................................................_.........._._........................_._..........................................................__._........................................................................................................ <br /> .................................. ... <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ®3.FIBERGLASS ❑ &EXTERIOR MEMBRANE LINER [17.JACKETED 445. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): a45a. <br /> ............................................................................................................._..._..........................................._.................__.._................_.._..__......_.................................... ........................ <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS [12.BALL FLOAT [13.FILL TUBE SHUT-OFF VALVE <br /> 452. <br /> [3 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 99.OTHER 460. <br /> ..................................................................................................-...............................----._.................................................................................................................-..................................................................................................._.._._....................._-....... <br /> .................................._........__._._.......................................................... 458 <br /> SYSTEM TYPE ❑ 1.PRESSURE ❑ 2.GRAVITY ® 3.CONVENTIONAL SUCTION .[_1 4:_SAFSAFE SUCTION[23 CCR§2636(a)(3)] <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ® 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a. <br /> ............ _................................................................................................._....................................................._............................................................................ <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ® 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c. <br /> __.._.._._..........................._.........._........................................................._......._................................................................................ ....................................................... <br /> PIPINGlrURBINE CONTAINMENT SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d. <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> 46 <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464e1. <br /> ..................._...................................._............................................................. .....4...4....... <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify): 464fl. <br /> .....................---.............................................................................................................................................................................._..................._.__............................................._................................................ ...4...4...:_.. <br /> VR PRIMARY CONTAINMENT ❑ I.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify): 464gg,.-. <br /> ...................................................................................................._....._....................._..............._..............................._......._.__..........................._...................................................................................................................................................................._._................................................................................................ 4 4 <br /> VR SECONDARY CONTAINMENT [11.STEEL ❑ 4.FIBERGLASS [I10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify): 464hl <br /> ...................................................................................................................................................._......._.._............................-. _........................................._............................................................................................................................................... <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ® 90.NONE 464i. <br /> ......................................................................................................................................................................................---...._...__............................................................................................................................................................................................... <br /> ,...._ <br /> 4641. <br /> RISER PRIMARY CONTAINMENT ❑ I.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464jk...., <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464kl. <br /> ........................._..................._..._..................................................-._.._........................._......................................................................................................................................................................................................................... <br /> ..................... <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ❑ 3.STRIKER PLATE/BOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 45la-c. <br /> VII. UNDER DISPENSER CONTAINMENT (UDC) <br /> CONSTRUCTION TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ® 3.NO DISPENSERS ❑ 90: 469a. <br /> ......................._.................._................................................................................................................._..................................................................................-_..._...................__..............._ .._ . . ...................................................................... . ................................................................... ........................................ <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) a,"I'll 469c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION r} 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provideLogein is true, <br /> accurate and in full com li ce with legal requirements. <br /> APPLICANT SIGNATURE _�9 ,1 DATE 8/12/2010 I 470. <br /> APPLICANT NAME(print) Todd Harris 471. APPLICANT TITLE Regional Environmental 4Ner 472 <br />
The URL can be used to link to this page
Your browser does not support the video tag.