My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4100
>
2300 - Underground Storage Tank Program
>
PR0231574
>
COMPLIANCE INFO_1986-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 11:45:21 AM
Creation date
6/23/2020 6:49:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2004
RECORD_ID
PR0231574
PE
2361
FACILITY_ID
FA0002123
FACILITY_NAME
GREWALS GAS & LIQUOR*
STREET_NUMBER
4100
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14333046
CURRENT_STATUS
01
SITE_LOCATION
4100 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231574_4100 E FREMONT_1986-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• i. �� Ur.IFlED PROGRAM CONSOLIDATED FOR , <br /> ' TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (two pages per tank) <br /> r <br /> Page _ of <br /> TYPE OF ACTION ❑1.NEW SITE PERMIT ❑ 4. AMENDED PERMIT ❑ 5. CHANGE OF INFORMATION) ❑ 6. TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7. PERMANENTLY CLOSED ON SITE 'v <br /> 3.RENEWAL PERMIT (Specify reason-for local use only) (Specify change-for local use only) ❑ S. TANK REMOVED 430 O <br /> BUPtVESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY IDN I'mi- <br /> LOCATION <br /> #WITHIN TE(OPRoneqL <br /> !/ d 1?'- q M /s1.TANK DESCRIPTION <br /> TANK ID# l G� y 7Gs'✓"�T TANK MANUFACTURER r- COMPARTMENTALIZED TANK Yes ❑ No <br /> la /s• 3 3� v t&SL 1� _A If'Yas',complete one page for each compartment. <br /> DATE INSTALLED(YEARiMO) 7 TANK CAPACITY IN GALLONS 7�'� NUMBER OF COMPARTMENTS <br /> HIM 2 �� <br /> ADDITIONAL DESCRIPTION(Forlocal use only) <br /> *:k IL TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE <br /> 10.1. MOTOR VEHICLE FUEL ia. REGULAR UNLEADED ❑nn 2. LEADED ❑ 5. JET FUEL <br /> (ll marked,complete Petroleum Type) Ib. PREMIUM UNLEADED ,LA 0. DIESEL ❑ 8. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑1c.MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑ 3. CHEMICAL PRODUCT <br /> COMMON NAME(/mm Hazardous Materials Inventory page) CAS#(from Hazardous Materials Inventory page) <br /> ❑ 4. HAZARDOUS WASTE(Includes <br /> Used Oio <br /> 1 1195, UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> (Check on@ item only) 'L 2. DOUBLE WALL EXTERIOR MEMBRANE LINER 1195. UNKNOWN <br /> ❑ 4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑ 1. BARE STEEL ❑ 3. FIBERGLASS/PLASTIC ❑ 5. CONCRETE ❑95. UNKNOWN <br /> (Check one Rem only) CW_2.STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE W/100%METHANOL 1199. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑ 1 BARE STEEL p(j. FIBERGLASS/PLASTIC ❑ 8. FRP COMPATIBLE W/100%METHANOL 1195. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑ 5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑95. UNKNOVM433 DATE INSTALLED <br /> OR COATING <br /> ❑ 2.ALKYD LINING ❑ 4. PHENOLIC LINING ❑ 6. UNLINED ❑99. OTHER <br /> (Check one Rem only) � For local use on <br /> OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC ❑ 3. FIBERGLASS REINFORCED PLASTIC J`-"'. UNKNOWN 434 DATE INSTALLED <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑ 4. IMPRESSED CURRENT ❑99. OTHER <br /> (Check one item only) ❑ 2. SACRIFICIAL ANODE (Forlocal use only) <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use only) OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED <br /> (Check all that apply) �'1 SPILL CONTAINMENT 1. ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br /> K2. DROPTUBE 2. BALL FLOAT ❑ 4. EXEMPT <br /> ❑ 3. STRIKER PLATE <br /> �' ...FV.�'1TkNK�.EAK"DETECTION. <br /> IF SINGLE WALL TANK(Check all that apply): IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item onl : <br /> VISUAL(EXPOSED PORTION ONLY) ❑ S. MANUAL TANK GAUGING(MTG) ❑ 1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> AUTOMATIC TANK GAUGING(ATG) ❑ 6. VADOSE ZONE 4ZL 2. CONTINUOUS INTERSTITIAL MONITORING <br /> 3. CONTINUOUS ATG ❑ 7. GROUNDWATER ❑ 3. MANUAL MONITORING <br /> 4. STATISTICAL INVENTORY RECONCILIATION(SIR)r ❑ 8. TANK TESTING <br /> BIENNIAL TANK TESTING El 99. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) - ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 TANK FILLED WITH INERT MATERIAL? <br /> gallons ❑Yes ❑No <br /> CUPAFORM(4/99) Formerly SWRCB Form B <br />
The URL can be used to link to this page