My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4100
>
2300 - Underground Storage Tank Program
>
PR0231574
>
COMPLIANCE INFO_2005-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 11:53:40 AM
Creation date
6/23/2020 6:50:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2012
RECORD_ID
PR0231574
PE
2361
FACILITY_ID
FA0002123
FACILITY_NAME
GREWALS GAS & LIQUOR*
STREET_NUMBER
4100
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14333046
CURRENT_STATUS
01
SITE_LOCATION
4100 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231574_4100 E FREMONT_2005-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
236
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI Psciev <br /> MONITORING SYSTEM CERTIFICATION ' �E <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16,Division 3,Title 23,California Code of JUN <br /> Regulations <br /> ENVIR01V446i <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared forR /T �` L <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system 0 , � CrH <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility <br /> N2mo- GREWALS GAS Bldg.No.: <br /> Site <br /> Aririracc• 4100 FREMONT ST City: Zip: <br /> Facility Contact <br /> Parcnn• RICK Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 4/26/2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicates ecific equi ment Inspected/serviced: <br /> Tank ID: 87 Tank ID: 91 <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: 420 ® Annular Space or Vault Sensor. Model: 420 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: FE PETRO ® Mechanical Line Leak Detector. Model: 99LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). 1 ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DSL Tank ID: NA <br /> ® In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: SPLIT W 91 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Surgn Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99LD 2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank G*arfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 5-6 <br /> ® Dispenser Containment Sensor(s). Model: 208 to Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 3-4 Dispenser ID: 7-8 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-i certify that the equipment Identified In this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification Is information(e.g.manufacturers'checklists)necessary to verify that this information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): DAVE WINKLER Signature: <br /> Certification No.: 5263373-UT License No: 08-1739 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2 STREET GALT,CA 95632 Date of Testing/Servicing: 4-26-2012 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />