Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Facility Name: Facility Phone: Date: <br /> GREWALS GAS&LIQUOR* (209)487-0480 April 05, 2018 <br /> Facility Address: CERS ID: <br /> 4100 E FREMONT ST, STOCKTON, CA 95215 10180875 <br /> Inspection Contact: Title: Phone: <br /> Rick Grewal Owner (209)986-0797 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: Consent Given By: <br /> 9 Inspection ❑O Photos ❑O Sample Rick Grewal, Owner <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Zane Nimmo 06/02/2019 Zane Nimmo 08/26/2018 <br /> Service Technician Manufacturer's Training: <br /> VMI, 01/08/19; VR, 08/28/19; TT, 03/31/19 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> li} zs R- •, � `,.. <br /> .lx „d s; <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees ❑V o R ❑COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R ❑COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted o V ❑R ❑COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ❑V ❑R ❑COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan ■V ■R COS <br /> 2634(d) E-F <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan ❑V ❑R ❑COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V ■R X OS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment o V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ■V ■R "To.,S <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V o R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ❑V ❑R ❑COS <br /> 114 CCR 2636(0 Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V ❑R o COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change w/in 30 days ❑V ❑R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ❑R ❑COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V ❑R ❑COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V o R ❑COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented ❑V ❑R ❑COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V ❑R ❑COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V ❑R o COS <br /> 122 CCR 26310) Failure to submit and maintain UST system component statement of compatibility for substance stored ❑V ❑R o COS <br /> on <br /> •tom a+u sr ':r <br /> ,� ...... �;° I+. ...sgr <br /> =:fir.«.. <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records o V o R ❑COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑V ❑R ❑COS <br /> FA0002123 PR0231574 SCO01 04/05/2018 <br /> EHD 23-01 Rev.09/22/16 Page 1 of 4 Underground Storage Tank Program OIR <br />