My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2551
>
2300 - Underground Storage Tank Program
>
PR0231659
>
COMPLIANCE INFO_1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 1:37:54 PM
Creation date
6/23/2020 6:50:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231659
PE
2361
FACILITY_ID
FA0003849
FACILITY_NAME
Verizon Business: MANTECA
STREET_NUMBER
2551
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
19801005
CURRENT_STATUS
01
SITE_LOCATION
2551 E LOUISE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231659_2551 E LOUISE_1985-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
477
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m 1-P 0 2 <br /> 1�IED PROGRAM CONSOLIDATED FORM • aj TANK: TA0165901 <br /> /j(�3/ PR#: PR0231659 <br /> FAC#: FA0003849 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check all that apply) Page 3 of 3 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑ 1.PRESSURE K.SUCTION ❑ 3.GRAVITY 458 ❑ 1.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 459 <br /> CONSTRUCTION [:11.SINGLE WALL ❑3.LINED TRENCH ❑ 99.OTHER 460 ❑ 1.SINGLE WALL ❑ 95.UNKNOWN 462 <br /> X2.DOUBLE WALL E-195.UNKNOWN ❑ 2.DOUBLE WALL ❑ 99.OTHER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100%METHANOL ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100%METHANOL <br /> ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN <br /> .FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER <br /> ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the mnitoring program sball be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑ 2.MONTHLY 0.2 GPH TEST ❑ 2.MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑ 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) ❑ 6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> ❑ 7.SELF MONITORING <br /> ❑ 7.SELF MONITORING <br /> GRAVITY FLOW <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH GRAVITY FLOW(Check all that apply): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑ c.NO AUTO PUMP SHUT OFF ❑ c.NO AUTO PUMP SHUT OFF <br /> ❑ 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> *;TI3. <br /> ION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> ❑ SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑ 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR JK6.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS 469 <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the infomtation provided herein is true and accurate to the best of my knowledge. <br /> SIGNATURE OF OWNER/OPERATOR 1 `� DATE - 470 <br /> NAME OF OWNER/OPERATOR(print) ``� TITLE OF OWNER/OPERATOR 471 wt%t(fA <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) 474 Permit Expiration Date(For local use only) 475 <br /> PT0005162 EE0000646 12/31/2002 <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.