Laserfiche WebLink
Amk <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />__[Date: <br />Facility Name: <br />Facility Address: <br />SUTTER TRACY COMMUNITY HOSP <br />1420 N Trac Blvd Trac <br />November 06 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. Secondary containment test <br />results for 2013 and monitoring system certification test results for 2014 were not found onsite. These records shall be <br />maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) results of <br />sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, <br />ground water elevations, or other test results; (6) results of inventory readings and reconciliations. Immediately locate <br />and maintain all maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br />The facility received copies of the secondary containment test results and 2014 monitoring system certification test <br />results from service company and copies were verified by inspector. This was corrected on site. <br />This is a minor violation. <br />204 <br />CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br />on site at all times. Immediately locate and retain a copy on site. This was corrected on site. <br />This is a minor violation. <br />208 <br />CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The January 2015 designated operator monthly inspection report was not found on site. Designated operator monthly <br />inspection reports for the previous twelve months shall be retained on site. Locate and ensure that copies of the <br />previous twelve months of designated operator monthly inspection reports are maintained on site. The facility <br />contacted the service company for a copy and the copy was verified by inspector. This was corrected on site. <br />This is a minor violation. <br />209 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training for 6 employees were not current. The last training for the 6 employees <br />were conducted in October 2014. The designated operator shall train facility employees for which he or she is <br />responsible in the proper operation and maintenance of the UST system once every 12 months. The training shall <br />include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Received by <br />Inspector: <br />Phone: <br />Date: <br />(initial): <br />CINDY VO, EH Specialist <br />(209) 468-8257 <br />11/06/2015 <br />Page 5 of 6 <br />