My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1420
>
2300 - Underground Storage Tank Program
>
PR0231736
>
COMPLIANCE INFO_2006-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 12:42:29 PM
Creation date
6/23/2020 6:51:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2018
RECORD_ID
PR0231736
PE
2361
FACILITY_ID
FA0002562
FACILITY_NAME
Sutter Valley Hospitals dba Sutter Tracy Community Hospital
STREET_NUMBER
1420
Direction
N
STREET_NAME
TRACY
STREET_TYPE
Blvd
City
Tracy
Zip
95376
APN
233-081-01
CURRENT_STATUS
01
SITE_LOCATION
1420 N Tracy Blvd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231736_1420 N TRACY_2006-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
485
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AEk <br />r --I <br />San Joaquin County low <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />SUTTER TRACY COMMUNITY HOSP <br />1420 N TRACY BLVD, TRACY <br />November 21, 2014 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR- Notice to Comply) <br />Item # <br />Remarks <br />106 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and not approved by the EHD. Monitoring equipment should be listed as Veeder <br />Root not Veteroot. Personnel responsibilities should list the hospital personnel assigned. The monitoring plan must be <br />uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary <br />changes, and submit for review by the EHD. This is a minor violation. <br />The response plan is not current and not approved by the EHD. Response plan has not been uploaded into the <br />California Environmental Reporting System. The response plan must be uploaded to the California Environmental <br />Reporting System (CERS). Immediately log into CERS, upload the completed form, and submit for review by the EHD. <br />Ensure a copy is available for inspection at any time. This is a minor violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations where <br />monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. This is a minor violation. <br />126 <br />HSC 25404(e)(4) Failed to report program data electronically. <br />A submission to the California Electronic Reporting System (CERS) for the underground storage tank (UST) program <br />did not have the Owner Statement of Designated UST Operator Complicance nor Response Plan uploaded into CERS. <br />Beginning January 1, 2014, all businesses are required to submit all new (or any changes to existing) UST information, <br />including: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response Plan, UST <br />Owner/Operator Written Agreement (if applicable), UST Letter from Chief Financial Officer, and Owner Statement of <br />Designated UST Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure to include any other <br />relevant activities and required fields. This is a repeat violation, Class 11. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 12-21-14. <br />Consent to perform the inspection, take photos and collect samples was given by Pedro Gonzalez. This facility's <br />designated operator is David Winkler (ICC expiration date: 3-10-16). The service technician was David Winkler <br />(ICC expiration date: 3-3-16), who had the following manufacturer's certifications: Veeder Root EXP. DATES <br />2-10-16 and SWRCB EXP DATES 3-31-17. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if <br />applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br />Compliance. <br />Phone: <br />Date: <br />TAnspector: <br />RIS VELOSO, Senior REHS <br />(209) 468-3453 <br />11/21/2014 <br />Pana d of S <br />
The URL can be used to link to this page
Your browser does not support the video tag.