Laserfiche WebLink
Ll <br />E <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web: www.s*qov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility <br />Name: Sutter Tracy Community Hosp'TitAddress. <br />Facility <br />1420 North Tracy Blvd, Tracy <br />Inspection <br />Date: Nov 29, 2011 <br />Facility <br />Pedro Gonzalez <br />Title: <br />Plant Operation Engineer <br />Or -'6032 <br />Contact: <br />Inspection <br />Type: <br />XRoutine XMonitoring System Certification Installation E Complaint — ID* Other: <br />(Authority HSC 25289) <br />Consent for. XInspection XSampling XPhotos Granted by: Title: <br />Monitoring <br />Panel: <br />Veeder-Root TLS -350 <br />Piping <br />I System: Pressurized XSuction Gravity <br />Overfill <br />Prevention: XMechanical Audible/visual <br />_r <br />UST <br />4 <br />Product <br />_] <br />------ ...... <br />DSL <br />I ......... <br />------------- I <br />--------------- <br />-------------- <br />---- ---------- <br />I ------------- I <br />-------------- <br />Designated <br />Operator. <br />Felix Ramirez <br />ICC Exp. <br />Date: 04/2012 <br />Violations: F_-' M1 -Release Detection 11 M2 -Release Prevention L,,M3—Both <br />On Site Service r, <br />'j <br />ICC Exp. Manufacturer's <br />Technician: <br />Date: Training: <br />VIOLATIONS <br /># Cl <br />C2 M Cod, section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />OMME <br />IMME <br />C1 = Class 1 violation; C2 = Class 2 violation: M = Minor violation <br />101 <br />HSC 25284 <br />No permit to operate <br />102 <br />HSC 25404.5 <br />Annual operating fees not paid <br />103 <br />HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks tem <br />104 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) MQ <br />105 <br />CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 <br />CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 <br />CCR 2637 <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (1) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 <br />CCR 2638 <br />(e) test notification not provided to the EHD at lea 48 hours nor to conducting an installation, repair, <br />ce <br />replament, calibration, or certification <br />110 <br />HSC 25291(f) <br />Annual line leak detector test not performed (MI) <br />ill <br />HSC 25284.2 <br />Annual spill containment testing not performed <br />112 <br />CCR 2636(0(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (MI) <br />113 <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 <br />CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 <br />CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 <br />HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />118 <br />HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 <br />HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 <br />HSC 25298(c) <br />Permit to close UST system not obtained <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/ years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />201 <br />CCR 2712(b) <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />I equipment, ground water elevations, or other test results; (6) results of inventory readings and reconciliations <br />202 <br />CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (Ml) <br />203 <br />CCR 2650 <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Thuy Tran (209) 468-8257 <br />EHD 23-02 Rev 09/01/11 Prge 1 .7 UST INSPECTION REPORT <br />