My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2004-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:30:52 PM
Creation date
6/23/2020 6:51:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2009
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\V\VICTOR\880\PR0231746\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' MONIARING SYSTEM CTIFI • TION <br /> For Use By All Jurisdictions Within the State of CRlifornia <br /> .fut6oriry Cited. Chapter 6.7,1�1ea11h and Safety Code; Chapter 16,Division 3, TFtle 23, California Code of Regulations <br /> This form most be used to document testing and servicing of monitoring equipment.A UgUAtg certification or report must be prepared for <br /> each monitoring system centrol panel by the technician who performs the work. A copy of this form most be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test <br /> date.A. General Information <br /> Facility Name: ECONO GAS Bldg.No.: <br /> Site Address' 880 E VICTOR ROAD City: LODI Zip: <br /> Facility Contact Person: SHAWN Contact Phonc No.: 209-468-3433 <br /> Make/1vlodcl of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 7-8-09 <br /> B. Inventory of Equipment Tested/Certiffed <br /> Check the appropriate boxes to indicate specific a ui ment inspecteWservicet I <br /> Tank ID: 87 Tank ID: 91 <br /> ®In-Tank Gauging Probe. Model: 847390-107 ®In Tank Gauging Probe. Model: 847390-107 <br /> Annular Space or Vault Sensor, Model: 794390.303 ®Annular Space or Vault Sensor, Model: 7943908303 <br /> ®Piping Sump/Trench Scnsor(s). Model: 80.208 ®Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ❑Fill Sump Set(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: _ <br /> ®Tank Overfill/High-Level Sensor. Model: 61-30 ®Tank Overfill/High-Level Sensor. Model: 61-80 <br /> ❑Otho(specify equipment type and model in Section 2 on Page 2). ❑Other(specify equipment type and model in Section 6 on Page 2). <br /> Tank ID: DIESEL Tank M., <br /> In-'yank Gauging Probe. Model: 847390.107 ❑In-Tank Gauging Probe, Model: <br /> ®Annular Space or Vault Sensor. Model: 794390.303 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 ❑Piping Sump/Trench Sensor(s). Madel: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model, <br /> ❑Mechanical Line Leak Detector, Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: 81.80 ❑Tank Overfill/High-Level Sensor, Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID; 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Senwr(s). Model: 794380.206 ®Dispenser Containment SensoKs), Model: 794380.208 <br /> M Shear Valve(s). ®Shear Vulve(s). <br /> ❑Dispenser Containment Float(s)and Cltain(s). ❑Dispenser Containment Float(s)and Chain(s), <br /> Dispenser ID: 5/6 Dispenser ID: 718 <br /> I@ Dispenser Containment Sensor(s). Model: 794380-208 Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shea Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chuin(s). ❑Dispenser Containment Ftoat(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: <br /> ®Dispenser Containment Sensor(s). Model: 794380.208 ❑Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). 0 Sherr Valve(s). <br /> ❑Dispenser Containment Fkt*s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> off the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Ce Cation-I certify that the equipment identified In this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certifieation Is information (e.g. manufacturers' checklists) necessary to verify that this information Is <br /> correct and a Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br /> attached a copy of the report;(check all that apply): X System set-up - arm history report <br /> Technician Name(print): JAMES WILLIAMS Signa <br /> Cerlif cation No.: A32464 �etme.No.: 433159 <br /> Testing Company Name: B.Z. Service Station Maintenance Phone No.:(916) 3712380 <br /> Site Address: 630 Houston Street West Sacramento,CA 95691 Date of Testing/Servicing: <br /> Page 1 of 3 <br /> UN-036-1/4 www.unidoes.org Rev.01/26106 I <br /> Z0oz NOI, VIS SDIAHEIS ZS 09CZ TLC 9T6 YU TC:£T OTOZ/OT/ZO <br />
The URL can be used to link to this page
Your browser does not support the video tag.